Hanwha SM481 PLUS Series Administrator’s Guide Eng.pdf.pdf - 第479页

15-43 System Setup Sets the time it takes generally fo r the tape feeder to feed the part once.  <Real T ransfer T ime> edit box Sets the time required to transfer the re el in order to supply parts from the tape …

100%1 / 566
15-42
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
<Mirror Open / Mirror Close> button
Opens or closes the mirror installed on the head module. Closing the mirror will allow
a user to check the nozzle tip with a vision system.
<Binary / Real> button
Shows the image seen through the Vision in real display to which threshold is not
applied, or in the image (Binary) to which threshold is applied as recognized by MMI.
15.6. Device [F11]
Controls the data related to the tape, stick and tray and nozzle.
15.6.1. Tape Feeder
The following screen shows that the ‘Tape’ is selected from the list box. Set the parameters
for the tape feeder.
Figure15.22 “Standard Device - Tape” dialog box
List box
Select the tape feeder type to be set up.
<Timing> group
<Open Time> edit box
Time needed to feed the tape feeder.
<Feeding Time> edit box
Time needed to feed the tape feeder.
<Normal Feeding Time> edit box
15-43
System Setup
Sets the time it takes generally for the tape feeder to feed the part once.
<Real Transfer Time> edit box
Sets the time required to transfer the reel in order to supply parts from the tape
feeder.
<Pickup Offset> edit box
Set the X offset value of the pick-up position of the tape feeder.Based on the setting of
the tape feeder in the front of the equipment, set the offset value of the pick-up
position of other feeders against the pick-up position of the 8mm tape feeder.
<Width> edit box
Sets the left and right width of the tape feeder based on the location pin of the tape
feeder. It is possible to calculate the space occupied by the tape feeders in the feeder
base using these parameters.
15.6.2. Stick Feeder
Next screen is the case where the “Stick” is selected in the Device list. Set the data on the
stick feeder.
Figure15.23 “Standard Device –Stick” dialog box
List box
Select the stick feeder type to set.
<Default Feed Time> edit box
Set the feed time.
<Width –Left> group
<Left> edit box
15-44
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
Set the left width of the stick feeder.
<Right> edit box
Set the right width of the stick feeder.
<Default Step> edit box
Set the basic number of sticks of each stick feeder according to the stick feeder type.
15.6.3. Tray Feeder
Next screen is the case where the “Tray” is selected in the Device list. Set the data on the
tray feeder
Figure15.24 “Standard Device –Tray” dialog box
List box
Select the tray feeder type to set.
<Default Step> edit box
Set the maximum number of pallets that can be placed on the single tray.
: Single Tray(5), FW-20NS(20), STF-100N(20), STF-100D(24), STF-100S(20) , STF-
100E(20).
<Width> edit box
Set the width of the tray feeder.