Hanwha SM481 PLUS Series Administrator’s Guide Eng.pdf.pdf - 第454页

15-18 Fast Flexible Placer SM481(L) PLUS Administ r ator’s Guide 15.4. L ight Mapping Calibrate the brightness of the light for t he camera. In order to perform this calibration, insert the LightFly or LightFix into the …

100%1 / 566
15-17
System Setup
Select the device to be taught first from <Device> in the <Teach> group and
insert the CN040 nozzle in the nozzle holder of the corresponding head.
Move the head to the dripping position.
Move down the spindle of the head until it contacts the disk surface. If the
nozzle end contacts with the disk surface, the change in the pneumatic
pressure occurs and the Z axis position is taught automatically.
<Use Flux Device> check box
This check box is selected to set the item related to the flux module.
<Churning> button
If this button is selected, the disk of the flux module rotates.
<Not Usable Lane> group
It sets the item related to the operation of the flux module.
<Feeder Base> button
Selects the feeder base on which the flux module is to be installed.
15-18
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
15.4. Light Mapping
Calibrate the brightness of the light for the camera. In order to perform this calibration,
insert the LightFly or LightFix into the No. 1 nozzle of the ANC.
Caution Since the nozzle for the SM32x,SM411, SM421 model is
not compatible to the one for the light mapping used for the
SM32x,SM411, SM421 model, do not use it for this
machine.
1: Light Level group
<Select Camera> combo box
Selection Control
Select the camera to perform light mapping.
Repeat this procedure for all fly cameras and fix cameras.
Light Level group
Sets the brightness by light level.
<Level> column
Dislays 16 steps of lighting.
<Side>/ <Outer>/ <Coaxial> column
15-19
System Setup
For the Fly Camera
Input the side illumination value within the range of 256 values.
For the Fix Camera
Input the side illumination value within the range of 4096 values.
<Back1> / <Back2> column
Enabled only when the fix camera was selected. The value within the range up to
4096 for each light level is inputted.
<Mapping/Test> button
Perform test or automatic mapping for the light level for the camera selected from the
<Select Camera> group.
Figure15.10 When the Fly Camera is selected