Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
Memo When activating the <Test> button, the Offset or Count cell must be
clicked.
The coordinate system in the following figure is obtained from the
cross hair center of the vision screen.
<Test> button
Sets the nozzle recognition condition and lighting condition by testing the binary value
of the pixel for the certain area (test box) that is set using the fly camera.
When the binary value of the pixel for the area that is used to check whether the nozzle
is mounted or not is below 30%, the nozzle is considered to be mounted. If the value is
above 30%, the nozzle is not considered to be mounted. If a nozzle actually exists, the
value must be close to ‘0’, if a nozzle does not exist, the values must be close to ‘100’.
<When the nozzle is mounted on the head>
14-13
Machine Calibration
<When the nozzle is not mounted on the head>
<Manual Tools> button
Clicking this button will execute the “Manual Control” dialog box by performing the
same function as selected by the in the View menu.
14-14
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
Head Mirror Teaching
The default value is 18. Can be different according to the system.
1) Select the Current Position( ) in the View menu to execute the
“Position” dialog box.
2) Click the <Manual Tools> button in the ‘Nozzle Check’ tab dialog box to
execute the ‘Manual Control’ dialog box.
3) Select Mirror in the <Axis> combo box of the Axis Tab dialog box..