7-76 Fast Flexible Placer SM481(L) PLUS Administ r ator’s Guide  Not Us e: Set this function so that it is not used.  Pi ck: S e t this function so that it is used only for pickup.  Mount : Se t this function so that …

100%1 / 566
7-75
Part Registration
Corresponds to the case that the tray feeder is selected in the <Feeder>
selection control. Sets the up/down movement of the pallet of a tray feeder
when supplying parts. The types of pitches that can be selected are as follows:
(1: Fastest, 5: Slowest)
<Placement> tab
Sets the parameters related to part placement.
<Soft Touch> combo box
This can be applied for the part pickup and placement. It allows the speed of the Z
axis to become 4 (slow) at 2mm height from the PCB upper surface when the head
moves down regardless of the speed set in the <Speed> group.
That is, the speed is controlled in 2 steps for the Z axis. For example, if cracks
occur frequently in the part. The overall speed of the Z axis may be reduced.
However, in this case, overall efficiency decreases.
At this time, the work can be done efficiently using this function.
7-76
Fast Flexible Placer SM481(L) PLUS Administrator’s Guide
Not Use: Set this function so that it is not used.
Pick: Set this function so that it is used only for pickup.
Mount: Set this function so that it is used only for placement.
Pick&Mount: Set this function so that it is used only for pickup and
placement.
Caution In case of shock sensitive components like CSP or μBGA,
the z-axis related speed parameters must be set according
to the component manufacturer’s specification or standards.
And use the nozzle suitable to component manufacturer’s
specification or standards.
If necessary, please contact our Business Department or
the local agent for the nozzle suitable to component
manufacturer’s specification or standards.
<Place Offset> group
It is possible to set the part placement offset.
<X Offset> edit box
It is possible to set the X offset.
<Y Offset> edit box
It is possible to set the Y offset.
<Z Offset> edit box
It is possible to set the Z offset.
<R (Place Angle> edit box
It is possible to set the R offset.
<ETC> tab
7-77
Part Registration
<Flux Type> selection box
Selects the method for flux part recognition. This function can be used for the
machine equipped with a flux device.
No Flux
Selected when the part is not a flux part. If this option is selected, the POP
function cannot be used.
Post Flux
Selected in cases to recognizes a part after dipping it into flux.
Pre Flux
Selected in cases to dips a part into flux after recognizing it.
<Flux Depth> edit box
Selects the depth of part dipping into flux. Set the depth based on '0' according to
the properties of the part.
<Flux Thickness> edit box
Input the thickness of the flux film formed on the table.
<Flux Dipping Time> edit box
Input the period of time during which a part remains dipped in flux. The default