Scope
This
test method covers acceptance of incoming
copper clad epoxy-glass laminates ranging in thickness from
0.8 mm to 6.5 mm, clad on one or both sides. It provides for
a standard method of inspection and establishes operations
that simulate the manufacture of PWBs. Specific values for the
acceptability are based on copper foil adhesion and visual
surface condition of the base laminate.
2
Applicable Documents
MIL-STD-105
Sampling
Procedures and Tables for Inspec-
tion by Attributes
MIL-P-13949 Plastic
Sheet, Laminated, Copper-Clad (For
Printed Wiring)
3
Test Specimen
3.1 Specimen
One
specimen shall be tested for each
sample, except in the case where material is clad on both
sides, in which case two specimens shall be processed for
each sample (one for each surface). Each specimen will have
four readings.
3.2
Sampling
The
sampling procedure will be to MIL-STD-
105. The inspection level shall be S-2 at 6.5 A.Q.L.
4
Apparatus
4.1
Complete
photo processing facilities
4.2
Etching
facilities
5
Procedures
5.1 Print and Etch
For
print and etch testing use 5.3.1,
5.3.2, 5.3.4, 5.3.5, 5.3.7, 5.3.8, 5.3.9, 5.3.10, and 5.3.11
only.
5.2
Print, Etch, and Plate
For
print, etch, and plate test-
ing, use 5.3.1 through 5.3.11 inclusively.
5.3
Steps
5.3.1 Preparation
5.3.1.1
Sand
the edges of the test specimens to remove
burrs, allowing close contact between the specimen, nega-
tive, and frame glass, resulting in a better defined etched pat-
tern.
5.3.1.2
Scrub
the copper surface(s) with FFF pumice and
brush to remove any contamination on the surface of the
specimen until it passes a water break test.
5.3.1.3
Dry
using compressed filtered air.
5.3.2
Apply Resist
5.3.2.1
Dip
the specimens in the following photo-resist solu-
tion:
• One part KPR III
• One part Toluene
• One part Acetone
All parts are by volume and should be used at room tempera-
ture. Specific gravity of the solution is 0.920.
5.3.2.2
Hold the specimen by one corner when dipping.
Allow excess solution to drain until dripping stops.
5.3.2.3
Put
the specimens on the rack (after draining) into
80°C oven for three to five minutes to dry and harden KPR.
5.3.2.4
Remove
the rack from the oven and allow the speci-
mens to cool to room temperature.
5.3.2.5
Place
the specimens upon the negative in the print-
ing frame with the copper side against the negative.
5.3.2.6
Expose
the mounted specimen for seven minutes,
75 mm from the fluorescent black light.
5.3.2.7
Develop
in trichlorethylene vapor for 15 seconds. It
may require two to six cycles until the pattern is clear. Air dry
the specimen after developing.
5.3.2.8
Use
artwork from MIL-P-13949.
5.3.3 Etch
per MIL-P-13949, Method A or B
The
Institute for Interconnecting and Packaging Electronic Circuits
2215 Sanders Road Northbrook, IL 60062-6135
IPC-TM-650
TEST
METHODS MANUAL
Number
2.3.1
Subject
Chemical
Processing, Suitable Processing Material
Date
4/73
Revision
Originating Task Group
N/A
Material
in this Test Methods Manual was voluntarily established by Technical Committees of the IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by the IPC.
P
age1of2
电子技术应用       www.ChinaAET.com
5.3.4
Drill
1.5 mm holes in the pads of the 3 mm lines with
good fabricating practice.
5.3.5
Remove the developed KPR by rubbing the pattern
lightly with cold trichlorethylene liquid. Rinse in water. Scrub
the specimens with FFF pumice and water with a strong
bristle brush.
5.3.6 Plate
(this is simulated plating) per MIL-P-13949.
5.3.7 Deoxidize
by dipping in 10% hydrochloric acid for two
minutes and wash in running water for five minutes. Dry 30
minutes, minimum, at 105°C to110°C.
5.3.8
Coat
the etched copper surface with white petrola-
tum. Specimens shall be immersed horizontally in solder 6.5
mm below the surface for 20 ± 1 seconds at 260°C +5/-0°C
measured 25 mm below the surface.
5.3.9
Remove
the petrolatum from the surface of the speci-
men with a two minute scrub in cold trichlorethylene, followed
by a one minute rinse in hot trichlorethylene.
5.3.10
Inspect
the surface for weave exposure, measling,
crazing, resin loss, delamination, and blistering.
5.3.11
Test
four 1 mm lines on the specimen for peel
strength per MIL-P-13949, reporting the average value for the
four lines.
IPC-TM-650
Number
2.3.1
Subject
Chemical
Processing, Suitable Processing Material
Date
4/73
Revision
P
age2of2
电子技术应用       www.ChinaAET.com
1.0
Scope
This
method evaluates the chemical cleanability
of metal-clad laminate surfaces of oxidation and anti-oxidation
protective coatings.
2.0
Applicable Document
None.
3.0
Test Specimen
The
size of the test specimen shall be
determined by the post etching tests to be performed.
4.0
Apparatus
4.1
Standard
conveyorized spray cleaning modules or suit-
able laboratory equipment.
4.2
Personal
safety equipment needed to perform this test
are as follows: rubber or polyethylene gloves, plastic or coated
apron and safety goggles.
4.3
Chemicals
4.3.1 Method A—Sodium Persulfate
Chemical Concentration Temperature
Cleaner/
Degreaser
Per manufacturer’s
recommended limits
As recommended
Sodium
Persulfate
1.5 lbs/gal
(± 0.5 lb/gal)
100°±5°F
(38°±3°C)
4.3.2 Method B—Ammonium Persulfate
Chemical Concentration Temperature
Cleaner/
Degreaser
Per manufacturer’s
recommended limits
As recommended
Ammonium
Persulfate
Tech Grade
2.0 lbs/gal
(± 0.5 lb/gal)
100°F Max
5.0 Procedure
5.1 Specimen Preparation
Shear the material to the
required specimen size and remove the rough edges from the
specimen by sanding or other suitable means.
5.2
Cleaning
5.2.1 Conveyorized Spray Cleaning
Process
the speci-
men through the conveyorized modules at a speed which will
permit 30 ± 5 seconds of exposure to the micro etching solu-
tion. Rinse specimens with deionized water for 1-2 minutes
after micro etching.
5.2.2
Laboratory Cleaning
Place
the specimen in a
cleaner/degreaser solution and gently agitate for 30 ± 5 sec-
onds. Remove the specimen and flush with tap water. Next
place the specimen in a micro etch solution for 30 ± 5 sec-
onds and vigorously agitate. Remove the specimen and flush
with deionized water for 1-2 minutes.
5.3
Surface Evaluation
The
metal cladding on the test
specimen shall be cleaned to a uniform matte finish. Deionized
or distilled water poured on the metal surface does not bead
or form puddles.
6.0 Notes
6.1
Sodium
persulfate solution shall be replaced if the cop-
per concentration exceeds 3.0 oz/gal (22.5 gal).
6.2
Solution
spray from nozzles should be checked for uni-
formity across the specimen.
The
Institute for Interconnecting and Packaging Electronic Circuits
2215 Sanders Road Northbrook, IL 60062-6135
IPC-TM-650
TEST
METHODS MANUAL
Number
2.3.1.1
Subject
Chemical
Cleaning of Metal-Clad Laminate
Date
5/86
Revision
B
Originating Task Group
N/A
Material
in this Test Methods Manual was voluntarily established by Technical Committees of the IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by the IPC.
P
age1of1
电子技术应用       www.ChinaAET.com