IPC-TM-650 EN 2022 试验方法.pdf - 第126页

1.0 Scope To determine the quality of the dielectric mate- rial after etching with ferric chloride. 2.0 Applicable Documents None. 3.0 Test Specimen Specimen 2 in. x 2 in. X thickness of one ounce or two ounces copper cl…

100%1 / 824
1.0
Scope
To
determine the quality of the dielectric mate-
rial after etching with ammonium persulfate.
2.0
Applicable Document
None.
3.0
Test Specimen
Specimen
2 in. x 2 in. X thickness of
one ounce or two ounces copper clad.
4.0
Apparatus
4.1 Heated Electrical Equipment
for
etching the speci-
men.
4.2
Air Circulating Chamber
capable
of maintaining 80°C ±
3°C (176°F).
4.3
Equipment and Chemicals
needed
to perform this test
are as follows: Rubber or polyethylene gloves, lint-free cloth,
grade FFF pumice and plastic scrubbing brushes, distilled
water, 10% solution oxalic acid, ammonium persulfate solu-
tion, methylethyl ketone, toluol, and trichlorethylene.
5.0
Procedure
5.1 Preparation of Specimen
Remove
rough edges from
the specimen by sanding or other suitable means.
5.2
Etching
Etch
specimen with vigorous agitation for the
minimum time in 66° BAUME ammonium persulfate solution
monitored at 43°C ± 3° (109.4°F). After removal of the copper,
immediately wash the specimen with running tap water for 2
to 5 minutes and keep the specimen from drying until the
specimen is placed in the chamber. Immerse the specimens
in a 10% solution of oxalic acid in distilled water 25°C ± 8°
(77°F) for 15 to 20 minutes providing gentle circulation of the
oxalic acid solution during this period. Flush the specimen
with tap water for 2 to 5 minutes, then scrub the specimens
with pumice to remove resist. Wipe the resist off with a lint free
cloth moistened with a suitable solvent. Scrub the specimen
with a plastic bristled brush under running tap water for 2 to 5
minutes. Rinse the specimen again in distilled water.
5.3
Condition
Dry
the specimens for 1 hour in a chamber
maintained at 80°C (176°F). If specimens are for electrical
tests, handle only with rubber or polyethylene gloves.
5.4
Evaluation of Test
Examine
specimens for white
deposits or other surface contaminants, loss of surface resin,
softness, delaminations, blistering or measling. Clad speci-
mens also should be evaluated for blisters or delamination of
the copper foil.
6.0 Notes
6.1
If
the etching time exceeds 15 minutes for 1 ounce cop-
per or 30 minutes for 2 ounces copper, renew the etching
solution.
6.2
Oxalic
acid is very toxic and extreme care should be
exercised.
6.3
The
time to produce a clean pattern with a minimum of
undercutting is approximately 7 minutes for 1 ounce copper
and 15 minutes for 2 ounces copper, using fresh solution.
The
Institute for Interconnecting and Packaging Electronic Circuits
2215 Sanders Road Northbrook, IL 60062-6135
IPC-TM-650
TEST
METHODS MANUAL
Number
2.3.6
Subject
Etching
Ammonium Persulfate Method
Date
7/75
Revision
A
Originating Task Group
N/A
Material
in this Test Methods Manual was voluntarily established by Technical Committees of the IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by the IPC.
P
age1of1
电子技术应用       www.ChinaAET.com
1.0
Scope
To
determine the quality of the dielectric mate-
rial after etching with ferric chloride.
2.0
Applicable Documents
None.
3.0
Test Specimen
Specimen
2 in. x 2 in. X thickness of
one ounce or two ounces copper clad.
4.0
Apparatus
4.1 Heated Electrical Equipment
for
etching the speci-
men.
4.2
Air Circulating Chamber
capable
of maintaining 80°C
± 3° (176°F).
4.3
Equipment and Chemicals
needed
to perform this test
are as follows: Rubber or polyethylene gloves, lint free cloth,
grade FFF pumice and plastic scrubbing brushes, distilled
water, 10% solution oxalic acid, ferric chloride solution, meth-
ylethyl ketone, toluol, and trichlorethylene.
5.0
Procedure
5.1 Preparation of Specimen
Remove
rough edges from
the specimen by sanding or other suitable means.
5.2
Etching
Etch
specimens with vigorous agitation for the
minimum time in 42° BAUME ferric chloride solution moni-
tored at 30°C ± 6° (86°F). After removal of the copper, imme-
diately wash the specimen with running tap water for 2 to 5
minutes and keep the specimen from drying until the speci-
men is placed in the chamber. Immerse specimens in a 10%
solution of oxalic acid in distilled water at 25°C ± 8° (77°F) for
15 to 20 minutes providing gentle circulation of the oxalic acid
solution during this period. Flush the specimens with tap
water for 2 to 5 minutes, then scrub the specimens with pum-
ice to remove resist. Wipe the resist off with a lint free cloth
moistened with a suitable solvent. Scrub the specimen with a
plastic bristled brush under running tap water for 2 to 5 min-
utes, then rinse for 30 minutes. Rinse the specimen again in
distilled water.
5.3
Condition
Dry
the specimens for 1 hour in a chamber
maintained at 80°C (176°F). If specimens are for electrical
tests, handle only with rubber or polyethylene gloves.
5.4
Evaluation of Test
Examine
specimens for white
deposits or other surface contaminants, loss of surface resin
softness, delamination, blistering or measling. Clad specimens
also should be evaluated for blisters or delamination of the
copper foil.
6.0 Notes
6.1
If
the etching time exceeds 15 minutes for 1 ounce cop-
per or 30 minutes for 2 ounces copper, renew the etching
solution.
6.2
Oxalic
acid is very toxic and extreme caution should be
exercised.
6.3
The
time to produce a clean pattern with a minimum
undercutting is approximately 7 minutes for 1 ounce copper,
and 15 minutes for 2 ounce copper using a fresh solution.
The
Institute for Interconnecting and Packaging Electronic Circuits
2215 Sanders Road Northbrook, IL 60062-6135
IPC-TM-650
TEST
METHODS MANUAL
Number
2.3.7
Subject
Etching,
Ferric Chloride Method
Date
7/75
Revision
A
Originating Task Group
N/A
Material
in this Test Methods Manual was voluntarily established by Technical Committees of the IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by the IPC.
P
age1of1
电子技术应用       www.ChinaAET.com
1.0
Scope
This
method is a means for preparation of test
specimens for determination of bare dielectric material quality
and properties, using cupric chloride as the etching solution
for removal of copper cladding.
2.0
Applicable Documents
IPC-TM-650
Method
2.3.1.1, Chemical Cleaning of Metal Clad Laminate
3.0
Test Specimens
The
size of lot samples or test speci-
mens shall be determined by the inspections or tests to be
performed after etching and the capabilities of the etching
equipment.
4.0
Apparatus or Material
4.1
Standard
chemical etching chamber or laboratory
equipment suitable to the etchant chemistry.
4.2
Air
circulating oven capable of maintaining the specified
temperatures and tolerances.
4.3
Personal
safety equipment shall include: rubber or poly-
ethylene gloves, plastic or coated apron and safety goggles.
4.4
Chemicals
Chemical Concentration
Cupric Chloride, CuCl
2
-2H
2
0
0.54 kg/l 4.5 lb/gal
Hydrochloric Acid, HCl 9.3% by weight (3N)
25% by volume
Distilled/Deionized Water As required
Sodium Hydroxide, NaOH 10% by weight
Reagent grade isopropyl alcohol
(IPA) As required
4.5
Pattern Developing Materials
Etch
resist system or
materials capable of producing the applicable conductor pat-
terns.
5.0
Procedure
5.1 Preparation of Specimen
5.1.1
Shear
the material to the appropriate sample or speci-
men size and if necessary remove the rough edges from the
specimen by sanding or other suitable means. Specimens
may be chemically cleaned in accordance with IPC-TM-650,
Method 2.3.1.1. Specimens may also be mechanically
cleaned.
5.1.2
If
a conductor pattern is required, prepare the material
by applying etch resist according to standard industry prac-
tices.
5.2
Etching
5.2.1
Remove
the metal cladding by etching in a spray
chamber or other suitable container containing 30-32*
BAUME cupric chloride solution maintained at 51.7 ± 5.6°C
[125 ± 10°F]. Etching time shall be minimized to prevent over-
exposure of the bare laminate material to the etching solution
and yet allow for complete removal of the exposed metal clad-
ding. If the specimens are etched in a laboratory environment,
vigorous agitation may be required.
5.2.2
Rinse
the specimens thoroughly.
5.2.3
For
referee purposes, neutralize any residual etchant
by quickly dipping in a 10% solution of NaOH solution and
then rinse thoroughly with distilled or deionized water. Note: If
this step is not followed, undercutting of the circuitry is pos-
sible, which in time could lead to inaccurate test data, such as
low peel strength.
5.3
Cleaning
5.3.1
If
etch resist has been used, samples shall have the
resist or tape removed by standard industry practices.
5.3.2
When
electrical testing is required on the material, do
not allow the etched specimens to dry before they go through
the cleaning process. For general testing, scrubbing with a
soft natural bristle brush under running tap water and rinsing
with distilled water or deionized water may be adequate. For
critical testing and for referee testing, laminates shall be
soaked for 10 minutes in reagent grade IPA followed immedi-
ately by a 10 minute rinse in flowing 16 megaohm deionized
water.
The
Institute for Interconnecting and Packaging Electronic Circuits
2215 Sanders Road Northbrook, IL 60062-6135
IPC-TM-650
TEST
METHODS MANUAL
Number
2.3.7.1
Subject
Cupric
Chloride Etching Method
Date
12/94
Revision
A
Originating Task Group
MIL-P-13949 Test Methods Task Group (7-11b)
Material
in this Test Methods Manual was voluntarily established by Technical Committees of the IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by the IPC.
P
age1of2
电子技术应用       www.ChinaAET.com