IPC-TM-650 EN 2022 试验方法.pdf - 第736页
3.4.2 Measure the flexible base dielectric thickness and the metal thickness of the twelve specimens by micrometer, cali- per or similar following the stabilization period in 3.4.1. Nomi- nal metal thickness to be tested…

photolithographic processes such that a minimum of twelve
good specimens are yielded at the end of 3.4.5. On the ‘‘Test
Surface,’’ etch four conductors 3.2 mm [0.126 in] wide,
5.7 mm [0.224 in] pitch, 230 - 250 mm [9 - 10 in] long on a
nominal 25 mm [1 in] wide strip of flexible base dielectric (see
Figures 1 and 2).
3.4 Conditioning and Aging Procedure
3.4.1
Twelve specimens, as described in section 3, shall be
subjected to a stabilization period of a minimum of 24 hours
at23°C±2°C[73.4 °F ± 3.6 °F] and 50% ± 5% RH.
IPC-2-6-21a
Figure 1 Construction of Specimens for Peel Strength Testing
Metal Conductor (4 each)
3.2 mm
[0.126 in]
25 mm [1 in]
(nom.)
230–250 mm [9–10 in]
5.7 mm
[0.224 in]
Table 1 Cleaning Process for Shiny Copper
Step Process Material Temperature Time
1 Soak Clean
Use commercially available acid or alkaline
cleaners
Per supplier recommended
temperature
Per supplier recommended
time
2 Rinse Running tap water Room Temperature 3 - 5 minutes
3 Microetch
Sodium persulfate: Two liters of deionized
water, 280 grams of sodium persulfate,
25 cc sulfuric acid
Room Temperature 1 - 2 minutes
4 Rinse Running tap water Room Temperature 1 minute
5 Acid Dip
Sulfuric acid 10% by volume, dilution 1.8
liters deionized water, 200 cc sulfuric acid
96% assay
Room Temperature 45 seconds
6 Rinse Running tap water Room Temperature 1 minute
7 Rinse Deionized water Room Temperature 1 minute
8 Dry Force air dry or blot with paper towels Room Temperature 1 - 3 minutes
9 Bake Bake in clean air-circulating oven 110±5°C[230.0 ± 9.0 °F] 10 to 15 minutes
10 Lamination
*Maximum delay between bake and
lamination shall be 30 minutes
*Lamination conditions (e.g., pressure, temperature, time, etc.) shall conform to suppliers’ recommendations.
IPC-TM-650
Number
2.6.21
Subject
Service Temperature of Metal-Clad Flexible Laminate, Cover
Material and Adhesive Bonding Films
Date
6/11
Revision
B
Page2of5

3.4.2 Measure the flexible base dielectric thickness and the
metal thickness of the twelve specimens by micrometer, cali-
per or similar following the stabilization period in 3.4.1. Nomi-
nal metal thickness to be tested is either 1 oz or 34.3 µm
[1350 µin] thick (preferred) or
1
⁄
2
oz or 17.1 µm [680 µin] thick.
3.4.3 On the specimens stabilized in 3.4.1, measure and
verify that the conductor widths are 3.2 mm ± 0.15 mm
[0.126 in ± 5.9 µin].
3.4.4 Examine the twelve specimens measured in 3.4.3
using normal or corrected 20/20 (also termed 6/6 or 1.0)
vision, and discard any peel strips showing the presence of
any wrinkles, cracks, blisters, or loose conductors. Twelve
specimens are required for the test, so any specimens not
meeting this criterion shall be replaced.
3.4.5 Per IPC-TM-650, TM 2.4.13, Method B, subject the
specimens examined in 3.4.4 to pre-drying and then solder
float.
3.4.6 Examine the specimens subjected to solder float in
3.4.5 using normal or corrected 20/20 (also termed 6/6 or 1.0)
vision. Discard any peel strips showing the presence of any
wrinkles, cracks, blisters, or loose conductors. Verify that at
least twelve good specimens remain.
3.4.7 Place six specimens into an air-circulating oven at the
desired Service Temperature value. The oven temperature
shall be held at a tolerance of ± 3°C [5.4 °F]. The specimens
are to continuously remain in the oven for 1000 hours, -0
hours / +12 hours.
3.4.8 After being aged per 3.4.7, the test specimens shall
be cooled to room temperature at standard ambient labora-
tory conditions. After being cooled to room temperature, the
thermally aged (oven conditioned) specimens shall be sub-
jected to a stabilization period of a minimum of 24 hours at
23 °C ± 2 °C [73.4 °F ± 3.6 °F] and 50% ± 5% RH.
3.4.9 After the stabilization period in 3.4.8, examine the
specimens using normal or corrected 20/20 (also termed 6/6
or 1.0) vision, and record the presence of any wrinkles,
cracks, blisters, or loose conductors, or any delamination.
3.5 Measurement of Peel Strength
3.5.1
AABUS, test specimens may have rigid reinforcement
material attached to all twelve specimens that were subjected
to the solder float in 3.4.5, including those six specimens that
were additionally subjected to thermal aging in 3.4.7. The rigid
reinforcement material shall not be attached prior to condi-
tioning and aging. The attachment of the rigid reinforcement
material depends on a number of factors, including the type of
peel test apparatus as described in IPC-TM-650, Method
2.4.9. If the rigid reinforcement material is to be utilized, it
should be adhered to the specimens using double-faced
adhesive tape or appropriate adhesive system to the back
side of the specimens.
If the test specimens are generated from double-clad flexible
base materials with metal remaining on the non-test side, the
additional rigid reinforcement material is unnecessary and
should not be used.
3.5.2 Measure the peel strength of the twelve conductors
per the procedures outlined in IPC TM-650, Method 2.4.9.
Specifically, peel the etched copper conductors away from
the dielectric at a 90° angle and at a 50.8 mm [2 in] per min-
ute crosshead speed.
3.6 Document and Report Results
3.6.1
Calculate the average peel strength of the six speci-
mens that were only exposed to the solder float (i.e., only as
per 3.4.5 and not exposed to the thermal aging of 3.4.7). Do
the same for the six thermally aged specimens per 3.4.7. Cal-
culate the ratio of the ‘‘thermally aged’’ average peel
strengths divided by the solder-floated only average peel
strength to determine the percentage retention of peel
strength. Record this number to ± 1% accuracy.
[Ave. of Six (6) Peel Strengths of Thermally Aged Specimens]
[Ave. of Six (6) Peel Strengths of Solder Floated-Only Specimens
x100=%ofPeel Strength Retained
IPC-2-6-21-2
Figure 2 Use of Adhesive Bonding Film to Form Test
Specimen
1 oz ED or RA Copper Foil Test Surface
(Shiny side toward the adhesive)
1 oz ED Copper Foil with Treated Matte
Side Inward as Support Material
Adhesive Bonding Film
IPC-TM-650
Number
2.6.21
Subject
Service Temperature of Metal-Clad Flexible Laminate, Cover
Material and Adhesive Bonding Films
Date
6/11
Revision
B
Page3of5

3.6.2 Report the results of the visual examination evaluation
in 3.4.9.
4
Dielectric Strength Using ASTM D-149 Test Procedure
4.1 Specimen Preparation
4.1.1
Prepare a specimen of the metal-clad flexible base
material large enough [approximately 400 mm x 500 mm
[approx. 16 in x 20 in]] to prepare at least twelve test speci-
mens each of 80 mm x 80 mm [approx. 3.0 in x 3.0 in]. Cover
materials shall be prepared per 3.2. Adhesive bonding films
shall be prepared per 3.3 where copper foil is used on both
sides of the adhesive bonding film.
4.1.2 Remove (etch) all metal from both surfaces of the
400 mm x 500 mm [approx. 16 in x 20 in] specimen by stan-
dard industry practice. Rinse the etched material thoroughly.
Cut the minimum of twelve test specimens to their nominal
size of 80 mm x 80 mm [approx. 3.0 in x 3.0 in].
4.2 Conditioning and Aging Procedure
4.2.1
After generating the minimum of twelve specimens as
described in 4.1.1, all specimens shall be subjected to a sta-
bilization period of a minimum of 24 hours at 23 °C±2°C
[73.4 °F ± 3.6 °F] and 50% RH ± 5% RH.
4.2.2 Examine at least twelve specimens using normal or
corrected 20/20 (also termed 6/6 or 1.0) vision, and record
any presence of any wrinkles, cracks or blisters. Discard those
specimens showing the presence of any wrinkles, cracks or
blisters.
4.2.3 Six specimens examined in 4.2.2 shall be placed into
an air-circulating oven at the desired Service Temperature
value. The oven temperature shall be held at a tolerance of ±
3 °C [± 5.4 °F]. The specimens are to continuously remain in
the oven for 1000 hours, -0 hours / +12 hours.
4.2.4 After being oven-conditioned as described in 4.2.3,
the test specimens shall be cooled to room temperature at
standard ambient laboratory conditions. After being cooled to
room temperature, the oven-conditioned specimens shall be
subjected to a stabilization period of a minimum of 24 hours
at 23 °C ± 2° C [73.4 °F ± 3.6 °F] and 50% ± 5% RH.
4.2.5 After the stabilization period in 4.2.4, examine the six
specimens that had been subjected to the oven- conditioning
using normal or corrected 20/20 (also termed 6/6 or 1.0)
vision, and record the presence of any wrinkles, cracks or
blisters.
4.3 Measurement of Dielectric Strength
4.3.1
The six specimens that were not subjected to the
oven-conditioning in 4.2.3 shall be subjected to the dielectric
strength test per ASTM D-149. (These measurements shall
be considered the ‘‘as-received’’ dielectric strength values.)
4.3.2 The ‘‘thermally aged’’ (oven-conditioned) specimens
examined in 4.2.5 shall be tested for dielectric strength
according to the conditions outlined in 4.3.1. (These measure-
ments shall be considered the ‘‘thermally-aged’’ dielectric
strength values.)
4.4 Evaluation of Results
4.4.1
Calculate the average dielectric strength of the six
‘‘as-received’’ specimens as measured in 4.3.1. Calculate the
average dielectric strength of the six ‘‘thermally aged’’ speci-
mens as measured in 4.3.2. Calculate the ratio of the average
value of the ‘‘thermally aged’’ dielectric strength divided by
the average value of the ‘‘as-received’’ dielectric strength to
determine the percentage retention of dielectric strength.
Record this number to ± 1% accuracy.
[Ave. of Six (6) Diel. Strengths of ‘‘Thermally Aged’’ Specimens]
[Ave. of Six (6) Diel. Strengths of ‘‘As Received’’ Specimens
x100=%ofDielectric Strength Retained
IPC-TM-650
Number
2.6.21
Subject
Service Temperature of Metal-Clad Flexible Laminate, Cover
Material and Adhesive Bonding Films
Date
6/11
Revision
B
Page4of5