IPC-TM-650 EN 2022 试验方法.pdf - 第741页

6.0 Notes 6.1 Care should be exercised when interpreting analysis results. Cp may not be meaningful if the X-bar or R charts are out of control, or the process capability histogram is grossly non-normal. Consult IPC-PC-9…

100%1 / 824
Each
thermocouple shall be secured using positive mechani-
cal means. For example, the thermocouple wire could be
wound around a piano wire secured across the width of the
ager.
The natural airflow within the ager should be preserved. Extra
baffles or wire mesh screens should not be included for this
test, if not used during regular solderability testing. Venting
should be preserved as it is during normal testing.
The end of the thermocouple, including the weld bead and
exposed wires, should be oriented vertically (pointing upward)
to prevent water drops from collecting on them.
5.3
Performing the Test
Turn
on the ager and allow to
stabilize until measurement procedures used during regular
testing indicate stability has been achieved.
Note:
Four
hours is usually required in most agers to
achieve stability, and this ‘‘warmup’’ time should be
included in the production part test procedure.
Start the test, logging temperature every 15 minutes for 8
hours. (if the data clearly indicates that the natural variability
within the chamber varies more quickly, the sampling fre-
quency can be increased as necessary)
When logging temperatures, all thermocouples should be
measured simultaneously, or within 2 minutes maximum.
Temperatures shall be recorded in degrees Celsius. Measure
temperature to the nearest 0.1 degree.
The steam agers shall not be disturbed during the test, except
for routine maintenance or inspection procedures; as used
during normal testing. The ager shall be tested without other
components inside.
5.4
Test Conditions
Test
the temperature stability at the
temperature set point used for solderability testing.
5.5
Data Analysis
5.5.1
Record
the following data for each test.
a. Ager manufacturer and model number
b. Temperature indicator type, date of calibration
c. Test date
d. Sampling frequency
e. Total vent area on chamber lid [sq.cm]
f. Total chamber cross-sectional surface area [sq.cm]
g. Total volume of air in chamber [cu.cm]
h. Set point temperature
i. Test location
i. in hood
ii. on table against wall
iii. on table in open room
j. Location of room air conditioning vents (include sketch)
k. Notes on any special conditions during test
l. Distance from thermocouples to water level
m. Location of thermocouples inside ager (include sketch)
n. Room temperature when testing
5.5.2
Test Data
Prepare
a matrix of test data, showing
temperature of each thermocouple at each sampling interval.
5.5.3
Control Charts
Prepare
X-bar and R charts with
appropriate control limits. A control limit calculation form is
shown in Appendix 1. Further instructions on preparation of
control charts can be found in IPC-PC-90 or ANSI/ASQC
Z1.1, Z1.2, and Z1.3.
Subgroups shall consist of all thermocouples placed in the
ager (8 or 10), and which are measured simultaneously during
the test.
The charts shall be considered out of control if any of the fol-
lowing applies:
a. any one data point is beyond the control limits
b. any 2 or 3 consecutive points are near a control limit (outer
third)
c. a run of 8 or more points is above or below the center line
d. a run of 6 or more points is increasing or decreasing
5.5.4
Process Capability Histogram
Prepare
a process
capability histogram, using data ranges of 1/2°C or less.
Estimate the mean and standard deviation of the data.
5.5.5
Process Capability Index
Calculate
the process
capability index, Cp using the equation shown below (from
IPC-PC-90 example 7.5.6.2) for specification limits of ±1°C
[±1.8°F], ±2°C[±3.6°F], ±3°C[±5.4°F] and ±4°C[±7.2°F].
Cp = USL-LSL
6S
Where,
Cp
= capability index
USL = upper specification limit
LSL = lower specification limit
S = process standard deviation
Include a plot of Cp against specification tolerance range.
IPC-TM-650
Number
2.6.23
Subject
Test
Procedure for Steam Ager Temperature Repeatability
Date
7/93
Revision
P
age2of3
电子技术应用       www.ChinaAET.com
6.0
Notes
6.1
Care
should be exercised when interpreting analysis
results. Cp may not be meaningful if the X-bar or R charts are
out of control, or the process capability histogram is grossly
non-normal. Consult IPC-PC-90 or ANSI/ASQC Z1.1, Z1.2
and Z1.3 for further details.
IPC-TM-650
Number
2.6.23
Subject
Test
Procedure for Steam Ager Temperature Repeatability
Date
7/93
Revision
P
age3of3
电子技术应用       www.ChinaAET.com
1
Scope
The
purpose of these tests is to characterize
changes in individual interconnection resistances as a function
of exposure time in various environmental aging conditions for
both flex to PWB and flex to indium-tin-oxide (ITO) coated
glass bonds.
2
Applicable Documents
IPC-3408
General
Requirements for Anisotropically Conduc-
tive Adhesive Films
3
Test Specimens
3.1
0.2
mm line/space test boards
0.2 mm line/space flex test circuits
4
Apparatus
4.1
ITO
coated soda-lime glass test slides, 20 ohms/sq. mm
4.2
Polypropylene
trays for sample storage in chamber
4.3
Instrumentation
to permit four-probe resistance mea-
surement
4.5
Required
environmental test chamber(s):
a) Thermal aging,
100°C
b) Thermal cycling,
-55°C to >125°C,
five hour period
c) Humidity aging,
60°C/95% RH
5
Procedure
5.1 Sample Preparation
5.1.1
Cut
the flex test circuits to the appropriate length (see
Figure 1 and Figure 2). If flex board samples are being pre-
pared, all traces on the flex should be shorted together on one
end.
5.1.2
Use
of new PCB is recommended. If new boards are
being used, there should be no need for any special cleaning
procedure. If used boards are to be used, they should be
inspected to ensure that:
a) Protective metalization (Au or Pb-Sn) is intact.
b) FR-4 isn’t significantly discolored from prior high tempera-
ture exposure.
c) The board is free of any residue from previous tests.
5.1.3
Refer
to 5.2 for proper bonding procedure.
5.2
Sample Procedure
5.2.1
Prepare
at least three test samples for each test con-
dition to be run. For the flex board case, it is possible to
mount two test samples on each board. Refer to IPC-3408 for
proper bonding procedure.
5.2.2
After
bonding is completed, each sample should be
identified by a test number. Test numbers should be written
on the test substrate using an indelible marker.
5.2.3 Clamp
the unbonded end of the flexible circuit to the
matching board traces to make electrical contact, with an
elastomeric compliant layer behind the flex to maintain uniform
contact force.
5.2.4
Initial
interconnection resistances should be measured
and recorded. The recommended measurement technique is
illustrated in Figure 3. This technique can be used with either
test sample type.
Note:
This
technique doesn’t allow for the measurement of
the first and last circuit trace. There are 15 measurements to
be made on each sample.
5.2.5
Samples
should be placed in the polypropylene trays,
and the trays placed in the appropriate chamber. The time
and date should be noted for the purpose of computing
elapsed time.
5.2.6
Samples
should be removed from the chambers for
resistance measurement after 24-hour, one-week, three-
week, and six-week time points. All environmental tests are
considered complete after six weeks. Samples should be
allowed to equilibrate at ambient conditions for at least 30
minutes prior to measurement.
5.2.7
All
resistance data should be tabulated and/or graphed
to facilitate proper interpretation of the results.
2215
Sanders Road
Northbrook, IL 60062-6135
IPC-TM-650
TEST
METHODS MANUAL
Number
2.6.24
Subject
Junction
Stability Under Environmental Conditions
Date
11/98
Revision
Originating Task Group
SMT Mounting Adhesives Task Group (5-24d)
Material
in this Test Methods Manual was voluntarily established by Technical Committees of the IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by the IPC.
P
age1of3
ASSOCIA
TION CONNECTING
ELECTRONICS INDUSTRIES
电子技术应用       www.ChinaAET.com