IPC-TM-650 EN 2022 试验方法.pdf - 第385页

1.0 Scope This test method specifies a qualitative method for assessment of the tackiness of soft soldering flux residues. The method is applicable to fluxes of types L and M. the method is particularly appropriate for a…

100%1 / 824
5.2.5
Remove
the coupon in a horizontal position and place
on a flat surface, allowing the melted solder to solidify undis-
turbed.
5.2.6
Repeat
steps 5.2.2 through 5.2.5 to test four addi-
tional specimens.
5.2.7
Use
a suitable solvent to remove all flux residue from
the test coupons.
5.3
Evaluation
5.3.1
Measure
each solder spread area by comparing to
circles (predrawn) with areas similar to those listed in Table 1.
Report the mean of the spread (area in mm
2
)
of the five tested
specimens.
Table 1 is intended as an aid in defining areas in mm
2
.
T
able 1 Typical Spread Areas Defined in mm
2
Diameter
in mm Area in mm
2
10.00
78.54
10.70 90.00
11.28 100.00
6 Notes
6.1 Safety
Observe
all appropriate precautions on MSDS
for chemicals involved in this test method.
IPC-TM-650
Number
2.4.46
Subject
Spread
Test, Liquid, Paste or Solid Flux,
or Flux Extracted from Solder Paste, Cored
Wires or Preforms
Date
06/04
Revision
A
P
age2of2
电子技术应用       www.ChinaAET.com
1.0
Scope
This
test method specifies a qualitative method
for assessment of the tackiness of soft soldering flux residues.
The method is applicable to fluxes of types L and M. the
method is particularly appropriate for applications where flux
residues are left in place on soldered electronic and electrical
equipment.
2.0
Applicable Documents
ISO 1634
Wrought-Copper
and Copper Alloy Plate; Sheet
and Strip
ISO
9453
Soft
Solder Alloys
ISO
9455
Parts
1 and 2 Soft Soldering Fluxes
3.0
Test Specimen
A
minimum of 0.035 grams by weight
is required per test for fluxes in solid or paste form. For liquid
fluxes, a volume sufficient to contain a minimum of 0.035
grams of non-volatile matter is required per test. For samples
of flux cored solder, a minimum 1 gram is required per test
and for solder paste, a minimum of 0.5 grams is required per
test.
4.0
Apparatus and Reagents
4.1 General
In
the test use only reagents of recognized
analytical quality and only distilled, or deionized, water.
4.2
Acid Cleaning Solution
Add
cautiously, with stirring,
75 ml of sulfuric acid (density 1.84 g/ml) to 210 ml of water
and mix. Cool, add 15 ml of nitric acid (density 1.42 g/ml) and
mix the solution thoroughly.
4.3
Degreasing
solvent, such as 2-propanol, acetone, tolu-
ene or petroleum ether.
4.4 Powdered
chalk.
4.5
0.5
mm thick copper sheet complying with ISO 1634:
Part 1, grad Cu - ETP, condition HA.
4.6
Acetone
4.7
Solder
wire, or pellets, complying with QQ-S-ALLOY
XXX or ISO 9453 grade S-Sn60Pb40.
4.8
Solder
bath, either circular with diameter not less than
120 mm, or rectangular with dimensions not less than 100
mm X 75 mm, containing tin-lead solder having a liquidus less
than 200°C. The depth of the solder in the bath shall not be
less than 40 mm. The bath shall be capable of being main-
tained at a temperature of 235 +/-5°C.
4.9
Cupping
Device. This shall be fitted with a 27 mm diam-
eter die and a 20 mm diameter ball.
4.10
Drying
oven, suitable for use at 110 +-2°C.
4.11
Tongs,
or other suitable mechanical device, to lift the
test piece from the surface of the molten solder bath.
4.12
Soft
brush, of diameter approximately 7 mm.
4.13
Ordinary
laboratory apparatus.
5.0
Procedure
5.1 Preparation of Copper Test Pieces
5.1.1
From
the sheet of half hard copper, approximately 0.5
mm thick (4.5), cut test pieces each 50 mm X 50 mm.
5.1.2
Clamp each of the test pieces, in turn, centrally onto
the 27 mm die of the cupping device (4.9). Using the 20 mm
diameter ball, make a depression in the center of each test
piece 3 mm deep, by forcing the ball into the die. One corner
of the test piece may be bent up to facilitate handling with the
tongs.
5.1.3
Immediately
before the test, use the solvent (4.3) to
degrease each test piece, and immerse the test pieces for 20
seconds in the acid cleaning solution (4.2). Remove the test
pieces from the cleaning solution, wash well under running
water, rinse in acetone (4.6) and dry by air blowing at room
temperature.
5.1.4
Test
For solid, paste and liquid flux samples:
5.1.4.1
Weigh
1.00 +/-0.05g of the solder wire or pellets
(4.7), previously degreased in the solvent (4.3), and transfer it
The
Institute for Interconnecting and Packaging Electronic Circuits
2215 Sanders Road Northbrook, IL 60062-6135
IPC-TM-650
TEST
METHODS MANUAL
Number
2.4.47
Subject
Flux
Residue Dryness
Date
1/95
Revision
Originating Task Group
Flux Specifications Task Group (5-24a)
Material
in this Test Methods Manual was voluntarily established by Technical Committees of the IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by the IPC.
P
age1of2
电子技术应用       www.ChinaAET.com
to
the center of the depression in one of the cleaned copper
test pieces (5.1).
Note:
This
may conveniently be done, if solder wire is used,
by forming the wire into a tight spiral.
5.1.4.2
If
the flux under test is in solid or paste form—weigh
between 0.035g and 0.040g of the solid or paste flux and add
this to the solder in the depression of the test piece.
5.1.4.3
If
the flux under test is in liquid form—first determine
it’s non-volatile matter content by the use of the method
described in ISO 9455: Part 1 or Part 2. Then add the appro-
priate volume of the liquid flux, to contain between 0.035g and
0.040g of non-volatile matter, to the solder in the depression
of the test piece. Evaporate the solvent at 60°C for 10 minutes
in the drying oven (5.3).
Note:
If
the liquid flux has low non-volatile content, it may be
necessary to add the flux in two increments, carrying out the
evaporation procedure after each addition.
5.1.5
For
flux cored solder samples. Degrease the surface
of a suitable length of the cored solder sample, using a cloth
dampened with the solvent (4.3). Weigh 1.00 +/–0.05g of the
degreased sample, form it into a small flat coil and place it in
the center of the depression in one of the cleaned copper test
pieces (5.1).
5.1.6
For solder paste samples. Weigh 0.50 +/–0.05g of the
solder paste sample into the center of the depression in one
of the cleaned copper test pieces (5.1).
5.2
Heating
the test piece.
5.2.1
Using
the tongs (4.11), or other suitable means, care-
fully lower the prepared test piece from 7.1 onto the surface
of the molten solder, maintained at 235 +/–5°C in the solder
bath (4.8).
5.2.2
Allow
the test piece to float on the solder bath until the
solder melts and leave the test piece in this position for a fur-
ther 5 seconds. Remove the test piece carefully from the bath
and allow it to cool, in air, in a horizontal position for 30 min-
utes.
5.3
Examination
of the test piece. Dust the surface of the
flux residue on the test piece liberally with the powdered chalk
(4.4). Lightly brush the chalked surface with the soft brush
(4.12).
5.4
Evaluation
If the chalk powder is easily removed by
brushing, the flux is deemed to be ‘‘not tacky.’’ If the chalk
powder cannot be removed by brushing, or can be removed
only with difficulty, the flux is deemed to be ‘‘tacky.’’
IPC-TM-650
Number
2.4.47
Subject
Flux
Residue Dryness
Date
1/95
Revision
P
age2of2
电子技术应用       www.ChinaAET.com