5.4 Evaluation 5.4.1 Calculate the peel strength per mm of width by mea- suring the strip width in mm, using the following formula: 1m m measured strip width in mm x observed pull force = peel strength / mm width 6 Notes…

5.3.2
Place
the keyhole plate over the peel strip with the tab
in the large hole and the strip centered in the slot.
5.3.3
Clamp
the keyhole plate to the base with the paper-
clips, making sure the alignment is not disturbed.
5.3.4
Attach
the hemostat to the tab so the peel will be 90°
to the strip (the hemostat should be attached to the chain with
the adapter and hanging from the tester jaws or force gage so
that the tab can be clamped without excessive bending or
damage).
5.3.5
Start
the vertical pull (5 cm per minute) with the test
head and initiate a chart recorder or visually observe the mini-
mum and pull force.
5.3.6
Lower
the head or force gage to position for starting
the next peel strip and repeat starting at 5.2.1.
IPC-2-4-8-1-2
Figure
2 Keyhold Horizontal Axis
10 cm ±
0.25 cm
(2) .138-32UN-2B
0.025 cm dia.
0.064 cm
± 0.05 cm
10 cm ± 0.25 cm
0.475 cm
± 0.025 cm
0.95 cm ±
0.025 cm
2
0.064 cm
AL Allo
y
0.475 cm
± 0.05 cm
0.95 cm ± 0.075 cm
3
MS 16995
SCR CAP SOC HD
10.5 cm
± 0.075 cm
AA6061 T651
0.475 cm
± 0.025 cm
1.9 cm
± 0.025 cm
0.4 cm
+ 0.013 cm
- 0.0075 cm
dia.
2 holes
0.32 cm thic
k
AL Alloy
AA6061 T651
1
GI
IPC-TM-650
Number
2.4.8.1
Subject
Peel
Strength, Metal Foil (Keyhole Method For Thin Laminates)
Date
1/86
Revision
P
age2of3
电子技术应用 www.ChinaAET.com

5.4
Evaluation
5.4.1
Calculate
the peel strength per mm of width by mea-
suring the strip width in mm, using the following formula:
1mm
measured
strip width in mm
x observed pull force =
peel strength/mm width
6
Notes
6.1
Peel
strength is usually the minimum peel strength
observed.
IPC-2-4-8-1-3
Figure
3 Chain to Hemostat Adapter
IPC-TM-650
Number
2.4.8.1
Subject
Peel
Strength, Metal Foil (Keyhole Method For Thin Laminates)
Date
1/86
Revision
P
age3of3
电子技术应用 www.ChinaAET.com

1.0
Scope
The
purpose of this test is to determine the peel
strength of metal cladding to the base laminate while at
elevated temperature; and to evaluate the base laminate
material after the peel strength test is completed for degrada-
tion due to the conditioning.
2.0
Applicable Documents
IPC-TM-650 Test Methods Manual
Method
2.4.8.1, Peel Strength, Metal Foil (Keyhole Method for
Thin Laminates)
Method 5.8.3, Peel Strength Test Pattern
3.0
Test Specimens
3.1 Size and Configuration
Specimens
shall be 50.8 mm
x 50.8 mm [2.0 x 2.0 in] by the thickness of the laminate.
Cladding test strips shall be as specified (see 5.1.2).
3.2
Quantity and Sampling
Unless
otherwise specified,
specimens shall be one lengthwise for each clad side and one
crosswise for each clad side. The outside 25.4 mm [1 in] bor-
der of the parent sheet or panel shall be excluded.
4.0
Apparatus or Material
4.1 Tensile Tester
A
tensile strength tester equipped with
a load cell, capable of measuring to the nearest 0.0045 kg
[0.01 lbs.] and a light load wire or chain and clamp at least
457 mm [18 in] long (its weight is included in the load cell cal-
culation). The clamp jaws must cover the entire width of each
peel strip tab. Any equipment or apparatus having the
described accuracy, precision, and reproducibility may be
used.
4.2
Hot Fluid Bath
A
fluid bath or pot capable of maintain-
ing the specified fluid at the specified temperature when mea-
sured 2.54 mm [1.0 in] below the surface.
4.2.1
Dow
Silicone Fluid No. 704, or equivalent.
4.3
Specimen Hold-down
A
suitable hold-down clamping
system equivalent in performance as that defined in IPC-TM-
650, Method 2.4.8.1.
4.4
Data Collection
For
qualification testing, a recording
system capable of permanent data retention incorporated into
the test apparatus.
4.5 Measuring
device capable of measuring from 0.000 to
12.7 mm [0.500 in] to within ± 0.0025 mm [0.0001 in].
4.6
Etch Resist Materials or Systems
4.6.1
Plater’s
tape, or equivalent, to act as etch resist for
strip formation of the specified widths (see 3.3 and 3.4).
4.6.2
Photoresist
system (printing, developing, and strip-
ping).
4.7
Etching
system capable of complete removal of metallic
cladding.
4.8
Circulating
air oven capable of maintaining 125 ± 2°C
[257 ± 3.6°F].
5.0
Procedure
5.1 Specimen Preparation
5.1.1
Cut
the specimens from the laminate sample. Speci-
mens shall be taken no closer than 2.54 mm [1.0 in] from the
edge of the laminate sheet as manufactured.
5.1.2
Specimens
shall be prepared with at least four resist
strips of 3.18 mm [0.125 in] width and then etched, cleaned
and processed using standard industry practices and equip-
ment. For qualification and referee testing the specimen shall
be photoimaged in accordance with the artwork shown in
Method 5.8.3 of IPC-TM-650 and reproduced here as Figure
1, except that tab ends are optional. Specimens shall be
etched so that the conductor strips on one specimen are in
one direction per Figure 1. Double clad laminate shall have
each side tested using separate specimens. The opposite
side cladding shall be either fully removed or left fully clad.
Separate specimens for both the warp and fill directions are
required for each side. For referee testing the cladding on the
opposite side shall remain.
The
Institute for Interconnecting and Packaging Electronic Circuits
2215 Sanders Road • Northbrook, IL 60062-6135
IPC-TM-650
TEST
METHODS MANUAL
Number
2.4.8.2
Subject
Peel
Strength of Metallic Clad Laminates at
Elevated Temperature (Hot Fluid Method)
Date
12/94
Revision
A
Originating Task Group
MIL-P-13949 Test Methods Task Group (7-11b)
Material
in this Test Methods Manual was voluntarily established by Technical Committees of the IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by the IPC.
P
age1of3
电子技术应用 www.ChinaAET.com