IPC-TM-650 EN 2022 试验方法.pdf - 第223页
1 Scope This test method uses pressure sensitive tape to determine the adhesion quality of platings, marking inks or paints, and other materials used in conjunction with Printed Boards. 2 Applicable Documents Commercial …

The measurement location can then be observed on the video
camera image and adjusted if necessary. The collimator area
indicated on the video image should fit entirely within the test
area of the sample specimen as seen in Figure 3. The sample
image is then focused with the autofocus feature of the instru-
ment.
A minimum of 5 measurements shall be made per measure-
ment location (0.060 in x 0.060 in pad). Using a polycapillary
instrument, the 5 measurements shall be made at different
locations on the pad or the instrument should be used in a
scanning mode across the pad. On each side of the test
specimen on which an electroless nickel coating has been
applied, three pads shall be measured. The Measurement
Report shall include as a minimum:
• Instrument used
• Size of the collimator
• Measurement time
• Excitation conditions
• Individual measurement results
• Statistical measurement parameters such as mean, stan-
dard deviation and relative standard deviation
• Specification Limits as required
• Operator, time and date
6 Notes
6.1 Measurement Results:
Table 2 demonstrates the excellent standard deviation
achievable (0.4 wt.-% for 60 s measuring time) for measure-
ment of P-concentration. It should be noted that a high total
spectral intensity of more than 50,000 cps is the result of very
high flux excitation by an instrument using a polycapillary X-ray
optic emitted from a relatively small measuring spot of less
than 50 µm Ø.
In the case of standard aperture beam collimation, the total
measuring time for similar precision is expected to be a factor
of 2-3 X longer.
IPC-2344-2
Figure 3 Positioning ofa1mmØCollimator on a 1.5 mm
x 1.5 mm [0.060 in x 0.060 in] ENEPIG Pad
Table 1 Measurement of Coating
Thickness and Phosphorus Content:
Typical achievable results for NiP/Cu/PCB samples
(1 mm collimator; measuring time 120 s)
CRM
Specified Values Measured Values
d (µm) %P d (µm) %P
CRM 1 5.20 (0.1) 0 5.29 (0.1) 0.0 (0.3)
CRM 2 7.35 (0.2) 0 7.43 (0.1) 0.1 (0.3)
CRM 3 1.2 (0.1) 8 (0.4) 1.2 (0.1) 7.7 (0.3)
CRM 6 2.89 (0.1) 10.6 (0.4) 2.88 (0.1) 10.7 (0.4)
CRM 4 6.9 (0.2) 9.0 (0.4) 6.5 (0.1) 8.9 (0.3)
CRM 5 5.90 (0.2) 11.2 (0.4) 5.7 (0.1) 11.1 (0.3)
CRM 7 11.20 (0.2) 11.3 (0.4) 11.2 (0.1) 11.4 (0.3)
Table 2 Evaluation of Measurement
Repeatability using a Polycapillary XRF:
5 Readings of the ENEPIG Sample shown in Figure 3.
Au Pd NiP wt-%P
Mean 0.049 µm 0.096 µm 3.2 µm 9.3
Standard
deviation
0.002 µm 0.002 µm 0.026 µm 0.413
50 nm Au/96 nm Pd/3.2 µm NiP9.3/Cu/PCB
(Small spot polycapillary instrument, measuring time 60 s)
IPC-TM-650
Number
2.3.44
Subject
Determination of Thickness and Phosphorus Content in
Electroless Nickel (EN) Layers by X-Ray Fluorescence (XRF)
Spectrometry
Date
03/16
Revision
Page4of4

1
Scope
This
test method uses pressure sensitive tape to
determine the adhesion quality of platings, marking inks or
paints, and other materials used in conjunction with Printed
Boards.
2
Applicable Documents
Commercial Item Description (CID) A-A-113
Tape,
Pres-
sure Sensitive, Adhesive.
3
Test Specimens
Any
preproduction, first article, or pro-
duction printed board. A minimum of three tests should be
performed for each evaluation.
4
Apparatus or Material
4.1 Tape
A
roll of pressure sensitive tape 3M Brand 600
1/2 inch wide or a tape as described in (CID AA-113), Type 1,
Class B, except that the tape may be clear. The shelf life of
the tape is one year.
5
Procedure
5.1 Test
Press
a strip of pressure sensitive tape, 50 mm
[2.0 in] minimum in length, firmly across the surface of the test
area removing all air entrapment. The time between applica-
tion and removal of tape shall be less than one minute.
Remove the tape by a rapid pull force applied approximately
perpendicular (right angle) to the test area. An unused strip of
tape must be used for each test.
5.2
Evaluation
Visually
examine tape and test area for evi-
dence of any portion of the material tested having been
removed from the specimen.
5.3
Report
The
report should note any evidence of material
removed by this test.
6 Notes
6.1
If
plating overhang breaks off (slivers) and adheres to the
tape, it is evidence of overhang but not an adhesion failure.
6.2
If
foreign material (oil, grease, etc.) is present on the test
surface the results may be affected.
6.3
Certification
of 3M Brand 600 1/2 inch tape to CID-A-A-
113 is not required. The 3M Brand 600 1/2 inch tape is avail-
able through most office supply stores.
2215
Sanders Road
Northbrook, IL 60062-6135
IPC-TM-650
TEST
METHODS MANUAL
Number
2.4.1
Subject
Adhesion,
Tape Testing
Date
05/04
Revision
E
Originating Task Group
Rigid Printed Board Performance Task Group
(D-33a)
Material
in this Test Methods Manual was voluntarily established by Technical Committees of IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by IPC.
P
age1of1
ASSOCIA
TION CONNECTING
ELECTRONICS INDUSTRIES
®
电子技术应用 www.ChinaAET.com

1.0
SCOPE
1.1
This procedure describes three methods to determine
the level of treatment transfer for treated copper foil.
2.0
APPLICABLE DOCUMENTS
ANSI/IPC-MF-150
‘‘Metal
Foil for Printed Wiring Applica-
tions,’’ October 1991, current revision.
ANSI/IPC-CF-152
‘‘Composite
Foil Specification,’’ current
revision
3.0
DEFINITION
3.1 Treatment
An
electro-mechanical or chemical process
applied to one or both sides of copper foil to enhance the
adhesion of the foil to the base laminate.
3.2
Treatment Transfer
Any
visible bond enhancement
that has transferred from the surface of the copper foil to the
laminate substrate.
4.0
EQUIPMENT
4.1
For
the Tape Transfer method a sample of the foil to
tested 152 mm x 152 mm.
4.1.1
3M
Scotch Brand #600 Tape 19 mm wide.
4.2
For
the Strip Transfer method a representative sample of
foil, pressed to four plies of 7628 FR-4 prepreg to produce a
0.028 ml laminate, or as agreed upon by user and supplier.
4.2.1
Etching
system capable of removing copper foil from
base laminate.
4.3
For
the Weight and Filter Paper method a sample of
treated foil at least 203 mm x 51 mm.
4.3.1
#2
Filter Paper strips at least 76 mm x 25 mm.
4.3.2
A
standardized weight of 250 grams with a 3/4 inch
surface
4.4
Visual Acceptance Standards
4.5 White Background
5.0 TEST PROCEDURE
5.1 Tape Transfer Method
5.1.1
Each
copper sample being tested will have tape 19
mm x 102 mm applied to the treatment side in the machine
direction of the foil. The tape should be firmly applied by hand.
5.1.2
Remove
the tape by quickly pulling on one end at an
acute angle.
5.1.3
The
tape should then be reaffixed, adhesive side down
on standard white paper.
5.2
Strip Transfer Method.
5.2.1
Image
a line on the laminate to a minimum of 1/8 inch
wide.
5.2.2
Etch,
clean and process using standard industry prac-
tices and equipment. If preferred, a cut or sheared sample
may be used.
5.2.3
Pull
the strip of foil back 1 inch to expose the area
directly under the foil.
5.2.4
Visually
examine this area by placing the laminate strip
against a white background and comparing the amount of
transfer with the standard.
5.3
Weight
and Filter and Paper Method
5.3.1
Place
the copper foil sample on a firm, flat surface
with the treatment side up.
5.3.2
Place
the #2 filter paper on the copper foil sample with
the rougher side of the paper against the foil.
The
Institute for Interconnecting and Packaging Electronic Circuits
2215 Sanders Road • Northbrook, IL 60062-6135
IPC-TM-650
TEST
METHODS MANUAL
Number
2.4.1.5
Subject
Determination
of Treatment Transfer
Date
5/95
Revision
A
Originating Task Group
Treatment Transfer
Material
in this Test Methods Manual was voluntarily established by Technical Committees of the IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by the IPC.
P
age1of2
电子技术应用 www.ChinaAET.com