IPC-TM-650 EN 2022 试验方法.pdf - 第658页

6.1.2 Comb Patterns Various ‘‘comb patterns’’ can be properly tested following the procedures in this document. The test points for comb patterns such as in Figure 3 are 1 to 2, 2 to 3, 3 to 4, and 4 to 5. Test points 1-…

100%1 / 824
IPC-263-01
Figure
1 Moisture and Insulation Resistance Test Graph
IPC-263-2
Figure
2 Insulation Resistance Coupon E (See Table 7-3), mm [in]
IPC-TM-650
Number
2.6.3
Subject
Moisture
and Insulation Resistance, Printed Boards
Date
05/04
Revision
F
P
age3of4
电子技术应用       www.ChinaAET.com
6.1.2
Comb Patterns
Various
‘‘comb patterns’’ can be
properly tested following the procedures in this document.
The test points for comb patterns such as in Figure 3 are 1 to
2, 2 to 3, 3 to 4, and 4 to 5. Test points 1-3-5 are connected
to the positive (+) terminal, and test points 2-4 are connected
to the negative (–) terminals of the resistance meter.
6.1.3
Production Board Testing
Occasionally,
production
boards must be tested in lieu of test patterns. When this is
required, one must use good judgment and select adjacent
conductors for wiring terminal lands for testing, because con-
ductor spacing and placement can affect test results.
6.2 Documented alternative cleaning procedures may be
implemented. As an example, if there is a concern that scrub-
bing will adversely affect test results, e.g., when the test
specimens have very fine spacing and/or are plated with soft
metals (tin/lead, gold, etc.).
6.3 If
printed boards are to be stored before coating, place
the boards in a dry noncontaminating environment.
6.4
Performance
specifications should specify the method
of test specimen preparation, test condition class, and any
deviations to this test method.
6.5
The
test chamber should be constructed out of materi-
als that will not corrode or add ionic contamination to the test
environment.
IPC-263-3
Figure
3 Typical ‘Comb Pattern’’ (from IPC-B-25A)
IPC-TM-650
Number
2.6.3
Subject
Moisture
and Insulation Resistance, Printed Boards
Date
05/04
Revision
F
P
age4of4
电子技术应用       www.ChinaAET.com
1 Scope This test method is used to determine the mois-
ture and insulation resistances of applied polymer solder mask
under two separate prescribed conditions of temperature and
humidity. One condition is described as Class T and the other
Class H. Raw material qualification testing is performed on
designated comb patterns. Production quality conformance
testing is performed on a standard ‘‘Y’’ pattern.
2 Applicable Documents
IPC-A-25A-G-KIT
1
Multipurpose One-Sided Test Pattern -
Gerber Format
IPC-SM-840 Qualification and Performance of Permanent
Solder Mask
J-STD-004 Requirements for Soldering Fluxes
IPC-A-600 Acceptability for Printed Boards
3 Test Specimens The IPC-A-25A-G-KIT artwork package
provides the Gerber files necessary for the fabrication of the
standard IPC-B-25A test board used with this test method.
3.1 Qualification Testing
3.1.1 Class H
Three IPC-B-25A boards using the D comb
patterns with 0.32 mm [0.0126 in] lines/spaces (see Figure 1).
Of which, two are to be coated and one uncoated with solder
mask according to the solder mask supplier’s recommenda-
tions.
3.1.2 Class T Three IPC-B-25A boards using the E and F
comb patterns with 0.41 mm [0.016 in] lines and 0.51 mm
[0.020 in] spaces (see Figure 1). Of which, two are to be
coated and one uncoated with solder mask according to the
solder mask supplier’s recommendations.
3.2 Conformance Testing IPC-B-25A board C (‘‘Y’’
shape) pattern with 0.64 mm lines/0.64 mm spacing [0.025 in
lines/0.025 in spacing] or pattern with minimum spacing on
the production board (see Figure 1), whichever has the small-
est line spacing, coated with solder mask according to the
solder mask suppliers recommendations.
4 Apparatus
4.1 Chamber
A clean chamber capable of programming
and recording an environment of 25±2°C[77±3.F]toat
least 65±2°C[149 ± 3.6 °F] and 90-98% relative humidity.
NOTE: This test requires a clean chamber and clean water
for repeatable test results. The following recommendations
are made:
Incoming water purity should be between 0.5 and 0.1
micro-siemens/cm.
Fresh deionized water should be used for each test, rather
than using a recirculating water sump.
Chamber workspaces should be cleaned at least every six
months.
1. www.ipc.org/onlinestore
IPC-2631-1
Figure 1 IPC-B-25A Test Board
3000 Lakeside Drive, Suite 309S
Bannockburn, IL 60015-1249
IPC-TM-650
TEST METHODS MANUAL
Number
2.6.3.1
Subject
Solder Mask - Moisture and Insulation Resistance
Date
03/07
Revision
E
Originating Task Group
Solder Mask Performance Task Group (5-33b)
Material in this Test Methods Manual was voluntarily established by Technical Committees of IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by IPC.
Page1of5
ASSOCIATION CONNECTING
ELECTRONICS INDUSTRIES
®