IPC-TM-650 EN 2022 试验方法.pdf - 第218页
1 Scope This test method is used to determine the ability of a solder mask to resist degradation by solvents and cleaning agents. 2 Applicable Documents IPC-SM-840 Qualification and Performance of Permanent Solder Mask I…

Analyzing conditions depends on the test devices, test speci-
mens, their composition and environment.
5.3 Calculation of Halogen Content Insert the concentra-
tion of halogen ion (Cl
-
/Br
-
) obtained in 5.2 in the following for-
mula to obtain halogen contents in the specimens:
Chlorine (wt%) =
{[Cl
-
concentration in the test fluid (ppm) x
Cl
-
Dilution ratio in the fluid] -
[Cl
-
concentration in the reference (ppm) x
Cl
-
Dilution ratio in the reference]} x
{quantity of test solution (ml) /
mass of the test specimen} x 10
-7
Note: For the bromine content, use the same equation but
insert Br
-
values in the place of Cl
-
.
Note: The dilution ratio is the amount of added water as com-
pared to the total amount of solution in the test flask. If the
amounts used were 50 ml each, the dilution ratio would be 2.
6 Report In addition to the general requirements for report-
ing, the report shall include:
a. Test method number and revision.
b. Date of the test.
c. Identification and description of the specimen.
d. Average chloride content of the five (5) specimens in ppm.
e. Average bromide content of the five (5) specimens in ppm.
f. Average total halogen content of the five (5) specimens in
ppm.
g. Any deviation from this test method.
h. Date of the test.
i. Name of the person conducting the test.
IPC-TM-650
Number
2.3.41
Subject
Test Method for Total Halogen Content in Base Materials
Date
04/06
Revision
Page3of3

1 Scope This test method is used to determine the ability of
a solder mask to resist degradation by solvents and cleaning
agents.
2 Applicable Documents
IPC-SM-840
Qualification and Performance of Permanent
Solder Mask
IPC-A-25A-G-KIT
1
Multipurpose One-Sided Test Pattern
3 Test Specimens Six (6) IPC-B-25A boards coated with
solder mask on the top side. Five are to be tested and one is
to be held as a control.
The IPC-A-25A-G-KIT artwork package provides the Gerber
files necessary for the fabrication of the standard IPC-B-25A
test board used with this test method.
4 Apparatus and Reagents
4.1
Reagent Grade 2-Propanol (Isopropyl Alcohol)
4.2 Deionized Water (DI Water) with resistivity ≥2MΩ-cm
and ≤10 MΩ-cm
4.3 10% Alkaline Detergent [by volume], which shall be
comprised of
• 5% alkanolamine
• 2.5% 2-butoxyethanol
• 2.5% glycol ether
• 90% DI Water
4.4 Monoethanolamine
4.5 Miscellaneous laboratory-ware (e.g., beakers, funnels,
storage bottles, graduated cylinders) including:
1) A hot plate capable of heating up to 65 °C [149 °F]
2) A thermometer capable of measuring accurately up to 100
°C [212 °F]
3) A vent hood, or performed with adequate ventilation
4.6 Thermometer with measurement uncertainty less than 2
°C [3.6 °F] and precision better than 1 °C [1.8 °F].
5 Procedures
5.1 Chemical Exposure
5.1.1
Prepare the solvents and cleaning agents as outlined
in Section 4 and Table 1.
5.1.2 Completely immerse one test specimen in each of the
solutions shown in Table 1. A new specimen is to be used for
each chemical.
5.1.3 After immersion, hang the specimens to dry for ten
minutes at ambient laboratory conditions.
5.2 Visual Examination
5.2.1
Visually examine each printed board with corrected
20/20 vision without magnification for delamination or surface
degradation such as cracks, tackiness, blisters or swelling of
the solder mask.
6 Notes
6.1 Safety
Operator should be trained and familiar with the
hazards inherent to the chemicals being used and analyzed.
Proper personal safety equipment, such as safety glasses,
gloves and splash apron, and adequate ventilation shall be
used.
1. www.ipc.org/onlinestore
Table 1 Exposure of Solder Mask
to Solvents/Cleaning Agents
Solvent/
Cleaning Agent
Temperature
(°C) [°F]
Time
(Minutes)
Isopropanol
Ambient
Laboratory Conditions
2
75% isopropanol/
25% deionized water
46±2°C[115 ± 3.6 °F] 15
10% Alkaline detergent 57±2°C[135 ± °F] 2
Monoethanolamine 57±2°C[135 ± °F] 2
Deionized water 60±2°C[140 ± °F] 5
D-Limonene
Ambient
Laboratory Conditions
2
Note: Record the ambient temperature and temperature measurement
uncertainty in °C.
3000 Lakeside Drive, Suite 309S
Bannockburn, IL 60015-1219
IPC-TM-650
TEST METHODS MANUAL
Number
2.3.42
Subject
Solder Mask - Resistance to Solvents and
Cleaning Agents
Date
03/07
Revision
Originating Task Group
Solder Mask Performance Task Group (5-33b)
Material in this Test Methods Manual was voluntarily established by Technical Committees of IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by IPC.
Page1of1
ASSOCIATION CONNECTING
ELECTRONICS INDUSTRIES
®

1 Scope The purpose of this test method is to measure the
thickness and phosphorous (P) concentration of chemically
(electroless) deposited nickel (Ni) coatings by (energy disper-
sive) X-ray fluorescence (XRF) analysis.
The measurement is nondestructive and noncontact, and can
be performed either in ambient atmosphere or under vacuum.
Measurements shall be made on a defined feature (equi-
valent to a typical SMT pad) of 1.5 mm x 1.5 mm [0.060 in x
0.060 in] or equivalent area, using a 0.6 mm diameter collima-
tor. This equates to a measuring spot size (analysis area) of
1 mm diameter.
This test method is designed primarily for failure analysis, pro-
cess qualification and process auditing. It is not intended for
daily production control, due to the complexity and cost of the
equipment required.
2 Applicable Documents
IPC-4556
Specification for Electroless Nickel/Electroless
Palladium/Immersion Gold (ENEPIG) Plating for Printed Circuit
Boards
IPC-4552 Specification for Electroless Nickel/Immersion
Gold (ENIG) Plating for Printed Circuit Boards
3 Test Specimen This test method is primarily designed
for measurement of the phosphorus content in ‘‘as plated’’
ENIG PWBs. Other ENIG or electroless nickel (EN) plated sub-
strate materials may also be tested using this method, includ-
ing flexible circuits, silicon wafers, aluminum or steel. The typi-
cal thickness range of the NiP layer on PWB substrates is 3 to
6 µm [118.1 to 236.2 µin]. The Phosphorous content can
range from0%to14%byweight. Minimum and maximum
thickness for single layers of electroless nickel required for
accurate determination of the P content is 0.5 µm to 25 µm
[19.7 µin to 984 µin]. The maximum thickness of gold present
on the surface of the specimen when tested shall be less
than 0.10 µm [0.004 µin]. For samples with thicker gold, the
gold must be removed by chemical stripping or Ion milling
prior to evaluation.
While this test method is also suitable for evaluating phospho-
rus content in ENEPIG samples, the thickness of both the
gold (Au) and palladium (Pd) layers needs to be considered.
The maximum thicknesses of the layers over the electroless
nickel on ENEPIG specimens when tested shall not exceed
0.05 µm [0.002 µin] of Au and 0.10 µm [0.004 µin] of Pd on
top of the EN layer. This constraint will impact measurement
of ENEPIG samples plated on the higher side of the current
IPC-4556 specification. For samples with gold thicknesses
above 0.05 µm [0.002 µin], chemical or Ion milling stripping
may be carried out prior to evaluation. With the gold removed,
the maximum thickness of palladium on a specimen when
tested shall be 0.25 µm [0.0098 µin].
Note: Electroless palladium deposits may also contain phos-
phorus and its contribution to the total phosphorus content
must be taken into account when reporting the phosphorus
content of the deposit.
The sample to be tested should be flat and ideally not popu-
lated with components in the area of measurement. If testing
is done on populated boards, consideration has to be given to
measurement location, such that none of the electronic com-
ponents block the fluorescent radiation from reaching the
detector, as described in Section 5.4.
The test specimen requires no other sample preparation.
4 Apparatus An X-ray fluorescence spectrometer consist-
ing of the following:
• A radiation source (X-ray tube with adjustable HV power
supply from 10 kV to 50 kV).
• A primary beam filter and safety shutter assembly.
• A video camera.
• An X-ray collimator or a polycapillary X-ray optic.
• An energy dispersive Silicon Drift Detector SDD (a device in
which charge carriers created by the incidence of X-ray pho-
tons on a high purity silicon substrate are directed to a mea-
suring electrode by an applied transverse electric field),
including electronics.
• Evaluation software capable of simultaneously measuring
coating thickness and composition of multiple layers. The
software of the instrument shall have the capability of mul-
tiple excitation modes. It is necessary to apply different exci-
tation conditions; a soft excitation for the excitation of P-K at
10 kV and a hard excitation for Ni-K at 50 kV.
• A programmable X-Y positioning stage (accurate positioning
is required especially if small areas are to be analyzed).
• The instrument must be able to record the Intensities of the
individual radiation components of the Phosphorous K
energy line (I
P-K
) and the Nickel K energy line (I
Ni-K
) with suf-
ficient precision.
3000 Lakeside Drive, Suite 105N
Bannockburn, IL 60015-1249
IPC-TM-650
TEST METHODS MANUAL
Number
2.3.44
Subject
Determination of Thickness and Phosphorus
Content in Electroless Nickel (EN) Layers by X-Ray
Fluorescence (XRF) Spectrometry
Date
03/16
Revision
Originating Task Group
Plating Processes Subcommittee (4-14)
Material in this Test Methods Manual was voluntarily established by Technical Committees of IPC. This material is advisory only
and its use or adaptation is entirely voluntary. IPC disclaims all liability of any kind as to the use, application, or adaptation of this
material. Users are also wholly responsible for protecting themselves against all claims or liabilities for patent infringement.
Equipment referenced is for the convenience of the user and does not imply endorsement by IPC.
Page1of4