6|Function description 6.1 Read this first! 6.1.1 Target readers group These instructions are intended for people who use, adjust, operate or service the machine. DANGER Personal injury or material damage due to inadeq…

100%1 / 695
6|Function description
6.16 Flux unit Flux application module: flux control (option) ...............................................................................263
6.17 Versascan (option) ........................................................................................................................................ 268
6.18 Versaeye inspection system (option)............................................................................................................269
6.19 Solder feed with turret bar container (option) ............................................................................................. 272
Ersa GmbH Operating Instructions_VF335_en|Rev. 14|30/11/2017 121/695
6|Function description
6.1 Read this first!
6.1.1 Target readers group
These instructions are intended for people who use, adjust, operate or service the
machine.
DANGER
Personal injury or material damage due to inadequate maintenance and improper
operation of the machine!
ü Use only qualified personnel!
a) The machine transport, assembly, connection, commissioning, operation or main-
tainance by people who are not sufficiently qualified and informed can cause
severe damage to the machine or damage to people.
b) Such work may therefore only be performed by properly trained personnel! This
personnel must be able to recognize the hazards that can be caused by the sys-
tem mechanical, electrical or electronic equipment.
c) The people who carry out such work must know and have understood the con-
tents of these instructions.
d) Any person involved in the installation, commissioning, operation and/or main-
tenance of the machine must have read and understood the contents of the
"Safety instructions" chapter, as well as the chapters which are relevant for the
specific activity!
6.1.2 Supplementary documents
NOTE
Supplementary documents
Supplementary documentation and service instructions are available for the machine
single modules. These documents can be found on the data carrier [product_data_se-
lective ], which is included in the delivery. Please refer to these documents if this in-
struction manual does not provide sufficient information on a certain subject.
Ersa GmbH Operating Instructions_VF335_en|Rev. 14|30/11/2017 122/695
6|Function description
6.2 Machine operation
The machine is operated using a Windows PC. Depending on your machine equip-
ment, you can operate via trackball, mouse, touch pad or touch screen associated
with a keyboard.
6.2.1 Checking the EMERGENCY stop function
Activation of the EMERGENCY stop pushbutton stops dangerous movements imme-
diately. The EMERGENCY stop function is available at any time and in all operation
modes.
DANGER
Dangerous electrical voltage!
Serious injury or death from electric shock!
ü The emergency STOP pushbutton does not disconnect the machine power supply!
Individual parts of the system are energized even if the emergency stop pushbut-
ton has been activated!
a) Do not use the emergency STOP pushbutton to disconnect the machine from
voltage!
b) Always switch the machine off using the main switch.
Checking the function
ü To check the EMERGENCY stop function:
a) Set the machine to the [Maintenance mode] operation mode.
b) Activate an EMERGENCY stop pushbutton.
c) Open the input dialogue [Messages].
ð The [Emergency stop] message must be displayed.
ð The red light of the signal lamp must flash.
ð If the EMERGENCY stop button has been pressed, dangerous machine
movements are no longer possible. The machine must then be in the
[Voltage supply OK] operating mode.
d) Release the EMERGENCY stop pushbutton again.
ð If the blue RESET button is available on the terminal:
e) press the blue RESET button.
f) Acknowledge the machine software message.
g) Repeat the procedure for all available emergency stop buttons.
ð The process has now been completed.
When EMERGENCY stop is triggered due to a malfunction,
ü reset the EMERGENCY stop pushbutton:
a) eliminate the malfunction.
b) Close all doors, hoods and covers of the machine.
c) Open the input dialogue [Messages].
d) Release the EMERGENCY stop pushbutton again.
ð If the blue RESET button is available on the terminal:
e) press the blue RESET button.
ð The process has now been completed.
Ersa GmbH Operating Instructions_VF335_en|Rev. 14|30/11/2017 123/695