Operating Instructions_VF335_en.pdf - 第45页

3|For your safety 3.2.11.3 Flux material tank / storage room danger zones This area comprises the storage room of the flux tank and the area between the spray nozzle and the board wetted with flux material. DANGER Fire…

100%1 / 695
3|For your safety
3.2.11.2 Flux material tank danger zone
This area includes the interior of the flux material container.
DANGER
Mixing different types of flux material is prohibited!
Ersa GmbH Operating Instructions_VF335_en|Rev. 14|30/11/2017 44/695
3|For your safety
3.2.11.3 Flux material tank / storage room danger zones
This area comprises the storage room of the flux tank and the area between the
spray nozzle and the board wetted with flux material.
DANGER
Fire hazard due to flammable vapours!
Possible personal and material damage!
a) Check the pressure container before putting it into the storage room.
b) Open the shutoff valve on the flux material tank only in the storage room!
c) Filling the pressure vessel in the storage room is prohibited!
d) Immediately clean up spilled flux or cleaning agents!
e) In addition, observe the safety notes in the [Maintenance and repair] chapter!
f) Notes on filling the storage tank can be found in the [Maintenance and repair]
chapter.
Ersa GmbH Operating Instructions_VF335_en|Rev. 14|30/11/2017 45/695
3|For your safety
3.3 Subject-related safety instructions
3.3.1 Handling electrical equipment
DANGER
Dangerous electrical voltage!
Serious injury or death from electric shock!
ü Work on the electrical system or the machine electrical devices must be under-
taken only by a skilled electrician or by properly trained people under the supervi-
sion and guidance of a skilled electrician in accordance with the electro-technical
rules.
a) Shut off the work area with a red and white safety chain and a warning sign.
b) Disconnect all the machine and system parts on which inspections or service and
repair work are carried out.
c) Parts which have been disconnected must first be checked for voltage, then
earthed and short-circuited as well as secured against being switched on again.
Isolate any adjacent live components.
d) Use only original fuses with the specified current rating.
e) Use only voltage insulated tools.
f) In case of faults in the power supply, switch off the system immediately.
3.3.2 Handling pneumatic equipment
CAUTION
Highly pressurized machine parts!
Personal or material damage due to pressurized machine parts or unexpected move-
ment of the mechanism!
ü Work on the machine pneumatic and hydraulic devices may only be carried out by
professionals with the appropriate skills.
a) Read pneumatic and hydraulic plans!
b) System sections and pressure pipes to be opened must be depressurized before
any repair or maintenance work!
3.3.3 Dealing with process materials and substances
CAUTION
Irritating substances!
Personal injury or property damage when dealing with oils, greases, chemicals!
a) Read the rules applicable to the product safety data sheets before use!
Ersa GmbH Operating Instructions_VF335_en|Rev. 14|30/11/2017 46/695