5|Commissioning
g) Repeat the procedure for all available EMERGENCY STOP buttons.
ð The process has now been completed.
When EMERGENCY STOP is triggered due to a malfunction,
ü reset the EMERGENCY STOP:
a) eliminate the malfunction.
b) Close all doors, hoods and covers of the machine.
c) Opening the edit dialogue [Messages]:
d) release the EMERGENCY STOP pushbutton again.
ð If the blue RESET button is available on the terminal:
e) press the blue RESET button.
ð The process has now been completed.
5.3.6 Setting time and date
ü To set the PC time to the local time.
a) Click on the
button in the top toolbar of the start dialog.
ð The [Weekly timer] dialog opens.
b) In the [Weekly timer] dialog, click on
.
ð The system time of the PC is transferred to the PLC, and the correct time is
set automatically.
c) Follow the instructions on the screen.
d) Enter the desired switching times in the weekly timer and activate it.
e) With respect to this, please read chapter [Weekly timer].
Ersa GmbH Operating Instructions_VF335_en|Rev. 14|30/11/2017 98/695
5|Commissioning
5.3.7 Indicator lamp: Perform light test
Open the setting dialog [Messages] to test the indicator lamp. With regard to this,
please read Chapter [Functional description].
Lamp test
ü Testing the lamps and the horn:
a) Click on the
button.
ð All lights of the signal lamp must be lit. The horn must sound.
ü If not all lights are illuminated, or if the horn does not sound:
a) Have the indicator lamp checked by a qualified electrician.
b) Have a qualified electrician replace damaged components.
ð The process has now been completed.
5.3.8 Checking the safety equipment
ü If hoods, protection covers and doors are fitted with safety switches:
a) Open caps, protection covers and doors.
b) Check that the corresponding error messages are displayed on the operator
terminal and signal lamp.
c) Close caps, protection covers and doors. Acknowledge messages.
d) Finally, check all system parts for proper operation.
Ersa GmbH Operating Instructions_VF335_en|Rev. 14|30/11/2017 99/695
5|Commissioning
5.3.9 Referencing modules
Referencing must always be carried out in the following cases:
After a breakdown of the CAN motors power supply
after pressing the emergency STOP
after a power failure
after switching off the main switch
after an adjustment
NOTE
Are any changes possible?
The [Module properties] user rights are required to access this dialog. Settings can
only be displayed if no name and password are logged in. In this case, press the [ESC]
key on your keyboard, or click on the [Cancel] button when a password is required.
For referencing, you must open the input dialog of the relevant modules. When ref-
erencing, the relevant reference limit switches are approached and the appropriate
module is referenced.
ü Should this not be possible, or referencing fail:
a) Identify the cause of the error in the [Messages] input dialog.
b) Correct the error, then acknowledge the message.
c) Carry out referencing again.
ü How to reference a module:
a) Set the machine to the [Maintenance mode] operating mode.
b) In the start dialog, open the settings dialogs of the module to be referenced:
Ersa GmbH Operating Instructions_VF335_en|Rev. 14|30/11/2017 100/695