6|Function description
Specifying a flux type in the soldering program
ü Entering a flux type:
a) In the start dialog click the button.
ð The soldering program editor will open.
b) Press the flux sprayer icon in the editor.
c) The [General additional data Flux unit 1] window appears:
user:
ersa
Soldering program editor General additional data
Program informations
Program name
Version:
Last modification by:
Infotext:
Conveyor
Conveyor width adjustment
Graphical
data
Process time
Process time
Fix horizontal permanently
Park position
Congestion position
Flux unit
General additional data
Maintenance mode
Flux unit 1
vessel 1
Flux material data
Fig.74: The [General additional data Flux unit 1] function.
d) In the [Flux material data] frame click on the [vessel 1] input field.
Name
Edit dialog Text
Name
Edit dialog Text
2092960010
ð The [Name] window appears.
e) Enter the flux name from the keyboard in the [Edit dialog: Text] input field or
read the code with a reader.
f) Click the
button.
g) The text will be saved.
Click on
to close the dialog.
a) Exit the editor. Save changes before exit.
ð The process has now been completed.
Ersa GmbH Operating Instructions_VF335_en|Rev. 14|30/11/2017 266/695

6|Function description
Production using the soldering program
ü Production start:
ü An acceptable program has been chosen.
a) Run the soldering program.
ð If no flux type is specified in the program, production will start irrespective
of the type of flux in the tank.
b) If a flux material type has been specified in the soldering program, the control
system will check if the data in the [Flux unit 1 - mount data] setting dialog
match those of the soldering program.
ð If data do not coincide, the program will not run and a message will be dis-
played.
ð If data coincide, the program will run.
ð The process has now been completed.
Soldering report data
If you work with a program where a certain flux type is specified, these data will
also be recorded in the soldering report.
Low flux level in the tank
When the flux level is insufficient, a message will appear which shall be acknow-
ledged after flux refilling. If in the [Flux unit 1 - mount data] setting dialog you have
defined a flux material type, an additional message will appear. It prompts you to
specify the flux type in the setting window again. Only then you will be able to ac-
knowledge the message and continue operation. See the section Specifying flux
material type in the setting dialog [Flux unit 1- mount data].
Ersa GmbH Operating Instructions_VF335_en|Rev. 14|30/11/2017 267/695

6|Function description
6.17 Versascan (option)
The code reader in the optional Versascan module at the machine infeed reads the
codes on the PCBs. As the code reader may be automatically moved, in case of mul-
tiple panels it is possible to read the code of each PCB of a workpiece carrier.
Moreover, the code reader reads the master code applied on the workpiece carrier
in order to assign a soldering program to it.
Further, the Versascan module can detect the allocation of the single panels of a
workpiece carrier. Empty panels may thus be excluded from the working cycle and
logging process. The component check function verifies whether the PCB is fully as-
sembled and makes sure that the relevant components are properly positioned.
The Versascan module is operated via an additional control terminal with separate
operating instructions.
NOTE
Additional documents
With regard to the scan module subject, please also read the documents in the
[Code_Scanner] folder on the [product_data_selective] data carrier included in the
scope of delivery.
Ersa GmbH Operating Instructions_VF335_en|Rev. 14|30/11/2017 268/695