Operating Instructions_VF335_en.pdf - 第52页
3|For your safety 3.5.3.1 Flux material refilling WARNING Risk of death or severe injuries due to flammable materials! Fire hazard! ü When performing any operation, observe the following safety rules: a) The machine su…

3|For your safety
3.5.3 Fluxer in general
DANGER
Severe or fatal injuries from flammable substances!
a) The exhaust air system must be fitted by the machine owner!
b) The required exhaust air volume can be referred to in Chapter [Technical data]!
c) The fluxer unit must not be put into operation before reaching the required
amount of exhaust air!
NOTE
Observe the rules! Risk of fire!
a) Have the fire protection system assessed at the installation site!
b) Take the necessary measures provided for by the applicable laws and regulations!
DANGER
Risk of death or severe injuries due to flammable materials! Fire hazard!
ü When working in the fluxer area:
a) Make sure that the machine suction system is switched on!
DANGER
Severe or fatal injuries from flammable substances! Risk of fire!
a) Service at the fluxer system may only be performed by qualified staff.
b) The fluxer system may not be changed or manipulated in any way.
ð When replacing the spray heads:
c) Only the spray heads intended for this machine may be used.
CAUTION
Personal injury or material damage due to irritant substances!
The fluxer system is under pressure!
a) Service and maintenance work may only be performed by qualified staff which
has been trained accordingly.
ð When working on the fluxer system:
b) First de-pressurize the system.
CAUTION
Wear protective clothing!
a) Wear a face mask and protective gloves!
Ersa GmbH Operating Instructions_VF335_en|Rev. 14|30/11/2017 51/695

3|For your safety
3.5.3.1 Flux material refilling
WARNING
Risk of death or severe injuries due to flammable materials! Fire hazard!
ü When performing any operation, observe the following safety rules:
a) The machine suction system must be switched on!
b) Read the safety data sheets of the flux material manufacturer!
c) Let the preheaters cool down: The temperature of the preheater must be clearly
below the flux material ignition temperature (also called self ignition point)!
d) Before applying the wrist earthing strap, make sure that it works properly!
e) Apply the wrist earthing strap and connect it to the equipotential bonding of the
machine!
f) Fill any removable flux material tanks outside the machine!
g) Remove immediately any spilled flux material and make sure that the room is suf-
ficiently ventilated. Restart the machine only after removing any residues!
3.5.4 Preheating in general
DANGER
Risk of burns from hot surfaces!
a) Touching the preheater during use is forbidden!
3.5.4.1 Preheater cleaning
DANGER
Risk of burns from hot surfaces!
a) Allow the heater to cool to room temperature before carrying out service and
cleaning work!
DANGER
Risk of personal and material damage due to flammable atmosphere!
a) Do not use flammable cleaning agents!
ð These can penetrate into the interior of the heater and ignite when switching
on again!
b) Immediately report any cracks or fissures in the glass plates!
c) Damaged glass plates must always be immediately replaced by qualified techni-
cians!
Ersa GmbH Operating Instructions_VF335_en|Rev. 14|30/11/2017 52/695

3|For your safety
3.5.5 Solder pot in general
DANGER
Severe or fatal injury from hot machine! Hot pot containing molten metal!
ü For any work being carried out, take the following safety precautions:
a) Touching the pot during operation is forbidden!
b) Allow the pot to cool down to room temperature before carrying out service and
cleaning work! On this regard, observe the solder temperature at the machine
terminal!
c) During the solder heating and cooling, molten metal can splash out of the pot!
The machine protective plates must therefore remain closed during heating and
cooling!
d) Open protective plates only when the solder has solidified completely.
e) Service and cleaning work on hot pots must always be carried out by trained and
qualified personnel!
WARNING
Electromagnetic fields!
Hazardous for people with pacemakers or implanted defibrillators!
a) In the soldering modules of this soldering system an electromagnetic pump is
used. During operation electromagnetic fields occur in the immediate area. Vul-
nerable people need to keep a minimum safe distance of 10 cm from the induc-
tion pump during its operation.
3.5.5.1 Servicing and cleaning the hot solder pot
WARNING
Severe or fatal injury from hot machine! Pot containing molten metal!
ü For any work being carried out, take the following safety precautions:
a) Service and cleaning work on hot pots must always be carried out by trained and
qualified personnel!
b) Create and follow an internal operating procedure for protective clothing!
CAUTION
Fine dust may irritate the skin, respiratory tracks and mucous membranes!
Wear suitable protective clothing and use suitable tools!
ü Please observe the following notes:
a) Do not use a household vacuum cleaner! This device should fulfil the M device
classification (or a better one).
b) Switch on the machine suction unit!
c) Wear gloves, respiratory protection and protective glasses!
d) Do not smoke, eat or drink!
e) Dispose of the dusts environmentally compatible!