10-6 Fast & Flexible Chip Shooter DECAN F2 Service Manual 10.2. Linear Scale 10.2.1. Required Tools T Wrench (other tools sup plied) or Hex W rench T orque Wrench S/W ABS ST700 Signal Adjustment Program ABS S…

10-5
Y-Axis Frame
X-Xy Compensation
Common X-Y (2'nd)
Thermal Mapping
Gantry Mapping
ANC, Position Teaching
S/W ABS ST700 Signal Adjustment Program - Homing Setting
Time: 1 hour
Ref In the case of the standard conveyor option, remove the machine from
the in-line system.
When removing the Y1 axis linear motor, remove/ assemble the X-
axis motor.
Remove/assemble the X-axis motor referring to the X-axis Motor
Replacement Procedure (Page 4-1).

10-6
Fast & Flexible Chip Shooter DECAN F2 Service Manual
10.2. Linear Scale
10.2.1. Required Tools
T Wrench (other tools supplied) or Hex Wrench
Torque Wrench
S/W ABS ST700 Signal Adjustment Program
ABS ST700 Signal Adjustment Program
CABLE-LINEAR_SCALE_GENDER(AM16-000377A)
CONVERTER,ELECTRIC-MULTI-1/USB COMBO(EP10-001948)
SM511_Y_LS_OFFSET_JIG (TO04-000898A)
0.4mm T Ruler
10.2.2. Location of Linear Scale
10.2.3. Linear Scale Replacement Procedure
1) Manipulate the perform homing of the machine.
2) Close the PC as usual and turn off the main switch at the front of the machine.
3) Remove the Cable that is connected to the Linear Scale.
4) Unscrew the fixing bolts (2-M3*10)securing the Linear Scale using a wrench and
remove it.

10-7
Y-Axis Frame
5) Assemble in the X Fame a new Linear Scale.
Ref The part number of the new Linear Scale is FC28-000159.
When replacing the Y frame linear scale, also replace the linear scale
in the other direction. Between Scale Unit and Scale Head to the
Assembly to 0.4mm. (0.4mmT a ruler)
6) Perform the following calibrations.
S/W ABS ST700 Signal Adjustment Program
- Signal Check normal
- SRE calibration Implementation
- Homing Setting
Time: 0.5 hour
7) For the setup method using the ABS ST700 Signal Adjustment Program, refer to the
following procedure.
Refer to the figure below, Connect the USB connection cable to the laptop
computer and Linear Scale Head Cable and check the set port values.