DECAN_F2_Service(Eng_Ver1).pdf - 第77页

3-15 Installation & Operation 2) Connect pneumatic line to the air main inlet. At this time, check if the air filter and mist separation filter are installed at the ma in air connection of the work place where the ma…

100%1 / 604
3-14
Fast & Flexible Chip Shooter DECAN F2 Service Manual
7) After checking the power supply setup, assemble the cover in the reverse order of
disassembling.
Ref Power Consumption: 5.0 KVA
Grounding: Based on the Class 3 grounding, it must be less than
100 when performing a Mega test with the machine for the
grounding line.
Caution When single phase current is taken off from the 3 phase
current, it is desirable to use 40% of the total capacity (kW)
as single phase current in order to prevent the machine
from being damaged due to distortion caused by the trip.
(Ex: When using a tray feeder)
3.1.6. Pneumatic Pressure Setup and Cable Connection
1) Unscrew the fixing bolts securing the cover at the rear bottom right of the machine and
remove it.
3-15
Installation & Operation
2) Connect pneumatic line to the air main inlet. At this time, check if the air filter and
mist separation filter are installed at the main air connection of the work place where
the machine is to be installed. (If the air pressure is insufficient, the yellow lamp of the
signal light is turned on)
3) Turn the regulator handle to adjust the pneumatic pressure to approximately
0.45~0.55MPa. (The air consumption of the machine is Max. 50 N/min. At this time)
3-16
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Ref Counterclockwise regulator rotation (pressure reduction),
Clockwise regulator rotation (pressure increase)
Main Regulator: 0.45~0.55 Mpa
Caution If the pneumatic pressure is out of the range 0.45 ~ 0.55
Mpa, a problem may occur in part pickup and placement
and feeder movement. Therefore, check the pneumatic
pressure before performing the work.
A compressor with appropriate capacity for the pneumatic
consumption of the machine must be used. Otherwise, the
reduction of the pneumatic pressure in the machine has
influence on the part placement quality.
Caution ?Since foreign materials including chips and burs can be a
problem after installing the pipe, clean the pipe using an air
gun with a clean cloth tied at the pipe end until the cloth that
is replaced after each cleaning becomes clean. Connect the
pipe to the machine when there is no fear of contamination.
Check if an oil filter and air dryer are installed in the air
piping system to prevent condensation.