DECAN_F2_Service(Eng_Ver1).pdf - 第549页

18-29 Machine Calibration Figure18.10“Teach Rails Edges” dialog box  <Edge Offset> edit box Means the distance from the center of the fiducial mark to the edge of the rail. T eaching must be performed after select…

100%1 / 604
18-28
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Ref #1: the first fiducial mark of the selected station
Ref #2: the second fiducial mark of the selected station
<Home> group
<Home All> button: Finds the homes of all axes.
<Teach> group
<Move> button
Moves the fiducial camera of the corresponding gantry to the position of the
fiducial mark selected from the Grid group.
<Get> button
Applys the coordinate value of the current position as the selected fiducial mark
position.
<Fiducial Teach…> button
Teaches the fiducial marks of the selected Station. Please refer to“6.3 Fiducial Mark
Setup”for more information.
<Edge Offset Teach…> button
Used to measure the offset between the fiducial mark and edge accurately. First click
the <Home All> button to measure the edge offset and check the fiducial mark
position.
18-29
Machine Calibration
Figure18.10“Teach Rails Edges” dialog box
<Edge Offset> edit box
Means the distance from the center of the fiducial mark to the edge of the rail.
Teaching must be performed after selecting this point using a mouse.
<Move> button
The <Move Cam> button can be clicked after first selecting a station and next
selecting the <Edge Offset> edit box. Then the downward camera (Fiducial
Camera) is moved to the center of the selected fiducial mark of the selected
station.
<Get> button
Apply the coordinate value of the current position as the selected fiducial mark
position.
<Light> button
Set the lighting value. Set the value by adjusting the sliding bar.
<Update> button
Applies the changed value and closes the dialog box.
<Shuttle Index Pos> group
Provides the function that can adjust the outlet position of the exit shuttle if the
position of the fixed rail of the conveyor does not match with the discharge position of
the exit shuttle in the following equipment.
This function is enabled only when the ‘Home’ function is performed for the conveyor
rail after booting the equipment.
18-30
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Figure18.11"Conveyor Calibration-Shuttle Index Pos " dialog box
<Pos Y> edit box
Refers to the coordinate of the outlet position (index position) of the current exit
shuttle.
<Shuttle Move> button
Moves the shuttle to the position inputted in the <Pos Y> edit box. However, if the
rear rail is fixed, it moves the shuttle to the position less the width of the current
rail.
<Shuttle Get> button
Sets the current shuttle position as the coordinate of the machine. Move the exit
shuttle using the jog function of the teaching box to match it with the fixed rail of
the next machine, and click this button to input the coordinate of the shuttle index
position in the <Pos Y> edit box.
In the case of the equipment with fixed rear rail, adjust the conveyor width so that
it becomes identical to the conveyor width of the following equipment, and move
the exit shuttle to the position that allows PCB transfer between two equipments
using the jog function and then click this button to save the coordinate of the
shuttle index position. At this time, input the value obtained by adding the width
of the current rail to the current position in the <Pos Y> edit box.
[Setup Sequence of the Jog Function of the Teaching Box]
Jog Conveyor Station Shuttle Axis