DECAN_F2_Service(Eng_Ver1).pdf - 第329页

13-59 Software To w e r Lamp 9 Opt Sig Part Empty Use 5 Const Use d with a combination of the following setup s: 1: Part Empty W arning (Y ellow/Blue) 2: Part Empty Error (Red) 4: PCB W ait W arring (Y ellow/Blue) 8: Byp…

100%1 / 604
13-58
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Tow er
Lamp
4 Opt Sig Type
Use
0
Const Types of tower lamps (used in the MMI)
5 Opt Sig Red
Use
2112
Const Setup for the tower lamp operation
6 Opt Sig Yel
Use
257
Const D0-D1: IDLE
D2-D3: RUN
D4-D5: PAUSE
7 Opt Sig Grn
Use
292
Const D6-D7: FREEZE
D8-D9: ADJUST
D10-D11: EMER
8 Opt Sig Blue
Use
0
Const 0: ACT_OFF
1 : ACT_ON
2 : ACT_BLINK
Module No Name Div Value Unit Description
13-59
Software
Tow er
Lamp
9 Opt Sig Part Empty
Use
5
Const Used with a combination of the following setups:
1: Part Empty Warning (Yellow/Blue)
2: Part Empty Error (Red)
4: PCB Wait Warring (Yellow/Blue)
8: Bypass (Safe Guard) Warring (Yellow/Blue)
15 Opt Buzon off
Use
2
Const 0: Always Buzzer On when an error occurs
1: Always Buzzer Not On when an error occurs
2: Buzzer On selectively when an error occurs
61 Opt PCB Wait
Warning Time
Use
20
Const When waiting for a PCB in the Run state, change the
tower lamp signal after the given period of time
(according to the No. 9 system constant setup).
Module No Name Div Value Unit Description
13-60
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Feeder 10 Opt IQ Feeder
Use
0
Const 0 : IT Feeder not used
1 : Front IT Feeder used
16 : Rear IT Feeder used
17 : Front and rear IT Feeder used
20 Opt Feed Over
Use
34
Const How to use a Feeder Unlock Sensor.
>> D0-D3 : Front D4-D7 : Rear
0 : No Check(NO) 1 : Check(CH) 2 : INT Check(INT)
Value: Front, rear
0 : NO, NO
1 : CH, NO
2 : CH-INT, NO
16 : NO, CH
17 : CH, CH
18 : CH-INT, CH
32 : NO, CH-INT
33 : CH, CH-INT
34 : CH-INT, CH-INT
22 Opt Tape Link
Use
0
Const Whether to use the Auto Link of the part supplied to a
tape feeder.
0: AUTO LINK
1: NOT LINK
Module No Name Div Value Unit Description