DECAN_F2_Service(Eng_Ver1).pdf - 第467页

17-55 Troubleshooting 2. Remove foreign materials in the pipes. 3. Inform the customer ’ s appoint ed representative of the problem.  1. Check the Air Regulato r for air leaking noise. 2. Clean and reassemble the Air Re…

100%1 / 604
17-54
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Replace the Y1 support unit bearing and support unit, reassemble the Y1 and Y2 ball
screws, and perform calibration.
Replace the support unit.
Reassemble the ball screw.
E0C03 Vacuum Generator Noise
[Cause]
The head filter case is damaged.
Defective vacuum generator (moisture penetration, etc.).
[How to Check]
1. Check the head for air leaking noise or check a specific head for low vacuum.
2. Clean and check the air line of the corresponding head.
3. Check the solenoid valve of the corresponding head.
1. Check the head for air leaking noise or check a specific head for low vacuum.
2. Clean and check the air line of the corresponding head.
3. Check the solenoid valve of the corresponding head.
4. Replace the vacuum generator.
[Measures]
Replace the vacuum filter case.
Replace the vacuum generator.
E0C04 Air leaks from the Air Regulator
[Cause]
The Air Regulator has been damaged.
Defective assembling of the Air Regulator.
Moisture or oil is discharged from the mist separator.
Defective main Air Regulator Black.
A problem occurred to the Mist Separator.
[How to Check]
1. Check the Air Regulator for air leaking noise.
2. Clean and reassemble the Air Regulator.
3. Replace the Air Regulator.
1. Check whether moisture or oil is carried over from the compressor.
(When repairing or replacing the compressor, moisture or oil is carried over from the
compressor.)
17-55
Troubleshooting
2. Remove foreign materials in the pipes.
3. Inform the customers appointed representative of the problem.
1. Check the Air Regulator for air leaking noise.
2. Clean and reassemble the Air Regulator.
3. Replace the Air Regulator.
1. When connecting the main air line, check the air line connection to the mist
separator.
2. Replace the mist separator.
[Measures]
Replace the Main Air Regulator (Mist Separator).
Clean and reassemble the Air Regulator.
1. Check whether moisture or oil is carried over from the compressor.
(When repairing or replacing the compressor, moisture or oil is carried over from the
compressor)
2. Remove foreign materials in the pipes.
3. Inform the customers responsible person of the problem.
Replace the Main Air filter.
1. When connecting the main air line, check the air line connection to the mist
separator.
2. Replace the mist separator.
E0C05 Air leaks from the head
[Cause]
Air leaks from the Head Air Module.
[How to Check]
1. Check the head for air leaking noise or check a specific head for low vacuum.
2. Clean and check the air line of the corresponding head.
3. Check the solenoid valve of the corresponding head.
[Measures]
Reassemble the bolts to the fittings.
E0C06 Vacuum Pump Noise
[Cause]
Noise is generated from the Vacuum Pump.
[How to Check]
17-56
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Check the Vacuum Pump for air leaking noise.
[Measures]
Check whether water or oil has entered the Vacuum Pump.
E0C07 Air leaking noise from the feeder base
[Cause]
A problem occurred to the feeder connection fitting.
[How to Check]
1. Replace and test the feeder.
2. Remove foreign materials from the feeder connection fitting.
3. Replace the connection fitting.
[Measures]
1. Replace and test the feeder.
2. Remove foreign materials from the feeder connection fitting.
3. Replace the connection fitting.
E0C08 Vibration and noise is generated when operating the conveyor belt
[Cause]
Defective drive and motor and defective contact.
A problem occurred to the tension and motor pulley.
[How to Check]
1. Check the motor cable and connector.
2. Check the idler for wear and belt jamming.
3. Replace the motor drive.
1. Check the conveyor belt tension.
2. Check the cables for defective contact.
3. Replace the driver.
4. Replace the motor.
5. Check whether the Motor Pulley is loosened.
[Measures]
1. Check the motor cable and connector.
2. Check the idler for wear and belt jamming.
3. Replace the motor drive.