17-65 Troubleshooting  Check all screws with a torque wrench of 140kgf/cm and tighten any that have loosened.  Reassemble the cable connected to the EMG of the MC1 and MC2.  Set the T win Servo Board Dip Switch again.…

100%1 / 604
17-64
Fast & Flexible Chip Shooter DECAN F2 Service Manual
2. Perform a homing operation test in the Ready On state.
3. Check that under what situation, the alarm occurs.
4. Check the assembling state of the LM Guide.
1. Check the status of the movement in the Y direction in the Ready Off state. (Check
for any problems with the movement.)
2. Perform a homing operation test in the Ready On state.
3. Check that under what situation, the alarm occurs.
4. Check the Servo Driver operation state.
(Check the assembling state of the power and encoder cables)
(Check the input and output voltage)
5. Check the assembling state of the terminal block and MC cables connected to the
Servo Driver.
6. Check the Twin Servo Board operation state.
7. Check the Axis Sensor Board operation state.
1. Check the status of the movement in the Y direction in the Ready Off state. (Check
for any problems with the movement)
2. Perform a homing operation test in the Ready On state.
3. Check that under what situation, the alarm occurs.
4. Check the Servo Driver operation state.
5. Check the voltage output and fuse of the Safety Control Board and DC Power
Board.
1. Check the status of the movement in the Y direction in the Ready Off state. (Check
for any problems with the movement)
2. Perform a homing operation test in the Ready On state.
3. Check that under what situation, the alarm occurs.
(Check the IO operation and sensor operation state)
4. Check the Servo Driver operation state.
(Check the assembling state of the power and encoder cables)
5. Check the Servo Motor operation state (Check the resistance of the power supply
section).
6. Check the variation of the main voltage.
[Measures]
Reconnect the 44B cable of the TB1.
After performing the Home Calibration, perform the Limit Calibration.
Replace the Servo Driver.
17-65
Troubleshooting
Check all screws with a torque wrench of 140kgf/cm and tighten any that have
loosened.
Reassemble the cable connected to the EMG of the MC1 and MC2.
Set the Twin Servo Board Dip Switch again.
Replace the Axis Sensor Board.
Replace the fuse in the safety control board and DC power board.
It is recommended that the AVR be used.
Replace the Servo Motor.
Reassemble the EMG terminal.
Replace the Y Motor.
Replace the Y-axis Servo Driver.
E0D08 Excessive skew occurs when operating the Y-axis
[Cause]
Defective system data
Defective Y1 Servo Driver
Environment has been changed.
Defective servo driver and defective contact due to equipment vibration (unknown
cause)
[How to Check]
1. Check the grease application state.
2. Move the X frame in the Y direction in the Ready Off state. (Check for any
problems with the movement)
3. Using the jog box, move the X frame in the Y direction in the Ready On state
(Check for any problems with the movement)
4. Perform skew compensation.
5. Check the operation state of the Servo Driver, Coupling, Motor and Ball Screw in
order.
[Measures]
Perform calibration.
Replace the Rear Motor Y1 Servo Driver.
Home all axes and perform skew calibration.
Reassemble the power connector at the R-Y2 Servo Driver.
E0D09 An error occurred while the gantry is homed
[Cause]
17-66
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Unstable voltage [momentary power failure]
Defective Axis Sensor Board (LED is not turned on when checking the Axis Sensor
Board)
[How to Check]
1. Check the status of the movement in the X direction in the Ready Off state. (Check
for any problems with the movement)
2. Perform a homing operation test in the Ready On state.
3. Check that under what situation, the alarm occurs.
4. Check the operation state of the Servo Driver, Coupling, Motor and Ball Screw in
order.
[Measures]
After approximately 1 hour has elapsed since the 24V power supply drop, check
whether the X-Y frame works normally.
Replace the Axis Sensor Board.
E0D0A An alarm occurs to the axis driving system sporadically
[Cause]
The FR Operate CN1 (Front or Rear Operation Panel) cable contact is defective.
Defective contact of the relay in the safety control board and DC power board
[How to Check]
1. Check the status of the movement in the X direction in the Ready Off state. (Check
for any problems with the movement)
2. Perform a homing operation test in the Ready On state.
3. Check that under what situation, the alarm occurs.
4. Check the operation state of the Servo Driver, Coupling, Motor and Ball Screw in
order.
[Measures]
Reassemble the FR Operate CN1 (Front or Rear Operation Panel) cable.
Reassemble the relay in the safety control board and DC power board.
E0D0B A follow-up error occurred to G1F-X
[Cause]
Defective X-axis Servo Driver
[How to Check]
1. Check the status of the movement in the X direction in the Ready Off state. (Check
for any problems with the movement)
2. Perform a homing operation test in the Ready On state.