Machine Calibration
box so that the fiducial mark on the calibration tool that is seen in the ‘SMVision’
window can be seen clearly. Then click the <Next> button.
9. In order to perform calibration, recognize the 2 fiducial marks on the bottom surface
of the calibration tool using the fly camera and put the calibration tool on the
calibration tool position on the ANC. Next, recognize the 2 fiducial marks at the edge
of the top surface of the calibration tool.
10. The calibration is performed automatically. If it is completed, the calibration result is
displayed as shown in the following figure. Click the <Next> button.
18-68
Fast & Flexible Chip Shooter DECAN F2 Service Manual
11. Then the message “Next, Remove the Calibration Nozzle From Head 1. Click [Next]
for Moving Down Head. After Moving, Remove the Nozzle Manually” appears. Click
the <Next> button to remove the calibration tool from the nozzle-holder of Head #1
manually.
12. Form Fly-Camera #2 to Fly-Camera #10, perform calibration in the same manner as it
was performed for Fly-Camera #1.
If the calibration procedure is completed for all fly-cameras normally, the result is
displayed as shown in the following figure.
13. Select Gantry 2 in the <Gantry> combo box and perform calibration in the same
18-69
Machine Calibration
manner as has done for Gantry 1.
The result value can be confirmed in the Camera dialog box in the System Setup
menu.
Memo The range of the reference values for the ‘fly-camera calibration’ is as
follows:.
FOV 16
ScaleX: 33.34~35.42 (m/pixel)
ScaleY: 33.34~35.42 (m/pixel)
FOV 16 (MEGA)
ScaleX: 15.39~16.35 (m/pixel)
ScaleY: 15.39~16.35 (m/pixel)
18.3.10.6. Fly Camera Offset Calibration
The following is the procedure to calibrate the offset of the fly Camera..In order to
perform ‘Fly-Camera Offset Calibration’, the ‘Fly-Camera Scale Calibration’ and ‘Head
Z-Offset Calibration’ must be performed first and the CN400 nozzle must be used.
The following is the procedure to calibrate the ‘Fly-Camera to Offset.
1. Click the <Nozzle Prepare> button and insert the CN400 nozzle into the No. 1 hole of
the ANC manually.
2. If the <11. Fly Camera Offset > is clicked after selecting the <Automatic Next> check
box, calibration is performed for the selected gantry automatically.
If calibration is performed after selecting the <No Real Motion [Manual]> check box,