DECAN_F2_Service(Eng_Ver1).pdf - 第433页
17-21 Troubleshooting Check whether the positio n of the Place Stopper is co rrect and move it s position to check whether the same problem occurs [Measures] Set the front/rear stopper again and perform conveyor cali…

17-20
Fast & Flexible Chip Shooter DECAN F2 Service Manual
E070C Optimizer Error
[Cause]
The CNT0 nozzle is registered to the ANC.
The part lead width is incorrectly set.
[How to Check]
Check whether the CNT0 nozzle is registered to the ANC.
Check whether there are any parts whose lead width exceeds the requirement of the
camera regarding the lead width.
[Measures]
Remove the CNT0 nozzle on the ANC.
Modify the part lead width.
E070D An error occurred that the front gantry fiducial camera recognized the fiducial mark
of the PCB transferred to the work station of the rear lane.
[Cause]
After the position of the Place Stopper had been changed, the stopper position was not
taught correctly.
[How to Check]
Check whether the position of the Place Stopper is correct and move its position to
check whether the same problem occurs.
[Measures]
Change the position of the Place Stopper.
E070E Exceeded the bad mark recognition range
[Cause]
After the position of the Place Stopper had been changed, the stopper position was not
taught correctly.
[How to Check]
Check whether the position of the Place Stopper is correct and move its position to
check whether the same problem occurs.
[Measures]
Change the position of the Place Stopper.
E070F The fiducial mark recognition position of the front and rear PCBs is different
[Cause]
The position of the Place Stopper is incorrect.
[How to Check]

17-21
Troubleshooting
Check whether the position of the Place Stopper is correct and move its position to
check whether the same problem occurs
[Measures]
Set the front/rear stopper again and perform conveyor calibration referring to the
Administrator’s Guide.
E0710 The confirmation window was not displayed when the fiducial mark recognition error
occurred
[Cause]
The <Use Manual Fiducial Teach> was not applied
[How to Check]
Select the General setup tab dialog box in the Preference submenu of the 'Sys. Setup'
menu and check whether the <Use Manual Fiducial Teach> check box is selected
[Measures]
After selecting the General setup tab dialog box in the Preference submenu of the 'Sys.
Setup' menu, select the <Use Manual Fiducial Teach> check box to apply the
corresponding function.
E0711 Failed to recognize the second PCB fiducial mark
[Cause]
Since the overall illumination is too bright and the area margin is set too widely, the
fiducial mark interferes with the mark nearby
[How to Check]
Perform a fiducial mark recognition test to check whether the brightness of the
illumination is appropriate. Then check whether the fiducial mark interferes with the
one nearby due to incorrect setup of the mark search area
[Measures]
Adjust the illumination brightness or change the area margin.
E0712 An error occurred when using an array fiducial
[Cause]
Incorrect system constant setup
[How to Check]
Check whether the No. 72 System Constant, ‘OPT FID DIST CHK’, is ‘0’
[Measures]
Set the OPT FID DIST CHK to '0'. (No. 72 System Constant)

17-22
Fast & Flexible Chip Shooter DECAN F2 Service Manual
E0713 Warning that the camera is not installed. CAM:2 …
[Cause]
The MMI system file is damaged.
[How to Check]
Check the camera setup in the Camera submenu of the Sys.Setup menu.
[Measures]
Reinstall the MMI software.
E0714 The DLL file cannot be found while executing the MMI
[Cause]
The MMI system file is damaged
Infected by a virus
[How to Check]
Perform HDD recovery and reinstall the MMI. Then check whether the same problem
occurs
Temporarily install an anti-virus program and check whether the file was infected by a
virus. (Delete the temporarily installed anti-virus program after inspection.)
[Measures]
Perform HDD recovery and reinstall the MMI.
If it is confirmed that the file was infected by a virus, remove the virus and then delete
the anti-virus program. If a problem occurs after booting or the system malfunctions,
perform HDD recovery
E015 When opening a file, even though the file name exists, the file is not opened
[Cause]
The MMI or Windows system file is damaged
[How to Check]
Perform a virus check of the HDD to check whether it has been infected. Format the
HDD and perform HDD recovery. Then reinstall the MMI and check whether the same
problem occurs
[Measures]
Format and recover the HDD and then reinstall the MMI.
E0716 When opening the PCB file, the PCB file in a certain folder was not opened
[Cause]
The PCB file created in the higher MMI version is opened in the lower version
[How to Check]