DECAN_F2_Service(Eng_Ver1).pdf - 第461页
17-49 Troubleshooting Check whether the power supp ly to the motor driver is appropriate. If it has no problems, replace the motor driver and check whether the same problem occurs [Measures] Check whether the power s…

17-48
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Replace the Magnetic Contactor.
E0B0A Defective SEDES Board (Applicable only to SM series machines excluding the
DECAN F2, SLM, SM471 and SM48X.)
[Cause]
Defective SEDES Board
[How to Check]
Check the SEDES Board operation state.
[Measures]
Replace the SEDES Board.
E0B0B Defective servo motor
[Cause]
Defective servo motor
[How to Check]
Check the servo motor power supply and the status of the encoder cable connection. If
it has no problems, replace the servo motor and check whether the same problem
occurs
[Measures]
Connect the servo motor power supply and encoder cable or replace the servo motor.
E0B0C The motor is overloaded
[Cause]
The motor is overloaded
[How to Check]
Check the alarm code
[Measures]
Eliminate causes of load of the corresponding axis.
Check the power supply cable of the motor.
Boot the machine again by turning the machine off and then on. If the problem occurs
continuously, replace the servo motor.
E0B0D Check the drive and power supply line
[Cause]
Defective drive and power supply line
[How to Check]

17-49
Troubleshooting
Check whether the power supply to the motor driver is appropriate. If it has no
problems, replace the motor driver and check whether the same problem occurs
[Measures]
Check whether the power supply is appropriate. If the problem occurs continuously,
replace the motor drive.
E0B0E The machine power supply has no problems but the power is not supplied to the motor
drive
[Cause]
The power supply line has a problem
[How to Check]
Check the main power supply
Check the status of CP2
Check the voltage between phases of the input voltage
[Measures]
Check the main power supply.
Check the status of CP2.
Check the voltage between phases of the input voltage.
E0B0C A Vibration or resonance occurs to a specific axis motor
[Cause]
Incorrect setup of the servo parameter and gain
Incorrect commutation offset value
[How to Check]
Modify the parameter and gain values related to noise and resonance
Measure the commutation offset value
Perform driver replacement test
[Measures]
Modify the parameter and gain values related to noise and resonance.
Modify the commutation offset value
Replace the motor drive.
E0B10 An Encoder related alarm occurred
[Cause]
An encoder related alarm occurred
[How to Check]

17-50
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Check the alarm code
[Measures]
Replace the motor drive.
Replace the motor.
Replace the cable with a normal axis cable.
Check the cable connecting the ZMP board and driver.
E0B11 Overvoltage related alarm occurred
[Cause]
Voltage is high.
[How to Check]
1. Check the input power supply.
2. Check the main input power supply.
[Measures]
1. Check the input power supply.
2. Check the main input power supply.
E0B12 Undervoltage related alarm occurred
[Cause]
Voltage is low.
[How to Check]
1. Check the input power supply.
2. Check the main input power supply.
[Measures]
1. Check the input power supply.
2. Check the main input power supply.