13-52 Fast & Flexible Chip Shoo ter DECAN F2 Service Manual V acuum 63 Sys Head V ac Delay Use 5 msec T ime delay from the Z Pulse End until the V acuum Sol Off signal is generated. 64 Sys Head V ac T ime Use 5 msec …

13-51
Software
ANC
25
Sys Delay ANC
Use
50 msec
Select the buzzer type.
26 NZ Get DN Margin
Use
1100 um
The distance through which the head moves down further
to pick a nozzle.
91 UZ Vis Use Chk Value Reser
ved
30 %
When checking for the existence of a nozzle using a
vision system, set the base for the nozzle existence
check to pixel 30%.
Module No Name Div Value Unit Description

13-52
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Vacuum 63 Sys Head Vac Delay Use 5 msec
Time delay from the Z Pulse End until the Vacuum Sol Off
signal is generated.
64 Sys Head Vac Time Use 5
msec Period of time from Vacuum Sol Off until the vacuum is
released.
65 Sys Head Vac Gen
Time
Use
20
msec Period of time from Vacuum Sol On until the vacuum is
created.
66 Sys Head Vac Rel
Time
Use 21
msec Period of time from Vacuum Sol Off until the vacuum
release is stabilized.
67 Sys Head Vac Time2 Reser
ved
170
msec Time of minimum variation when releasing the vacuum.
71 Sys Offset Vac Use 40 um
For the Z measurement using a vacuum, the difference
between the measurement vale and actual value.
Difference in measurement value when using the CN040.
96 Vac Close Detect
ABS
Use
613 mmHg
Absolute value based on when the nozzle is clogged
(used for Z offset, etc.).
97 Vac Close Detect Diff
Use
60 mmHg
Difference in measurement value based on when the
nozzle is clogged (used for Z offset, etc.)
Module No Name Div Value Unit Description

13-53
Software
Align /
Mount
62
Sys Fly outer Level Use
519
Const Set the control algorithm for the outer illumination of the
fly camera.
68 Small Comp Method
Use
15
Const Method related to the Small Comp.
70 Small Comp Size
Use
620 um
Standard size of the Small Comp.
72 Very Small Comp
Method
Use
7
Const Method related to the Very Small Comp.
73 Very Small Comp
Size
Use
380 um
Standard size of the Very Small Comp.
94 Fly Inspr Method
Use
3
Const 0: Recognition by the fly camera after rotation
(Recognition using placement angle).
1: Rotation after recognition by the fly camera (0 degree
recognition).
2: Rotation after recognition by the fly camera.
However, the fly camera will recognize a part after
rotating in the case of a 45° feed angle and FineGrab.
3: Rotation after recognition by the fly camera.
However, the fly camera will recognize a part after
rotating in the case of a 45° feed angle, FineGrab and
FinePitch.
Module No Name Div Value Unit Description