18-11
Machine Calibration
Set the resolution of the camera in X direction. The unit used is the number of
pixels per mm.
<Y> edit box
Set the resolution of the camera in Y direction. The unit is the number of pixels
per mm.
<R> edit box
Setup the R-axis assembling condition of the camera. The unit is degree.
<Offset Data> group
Sets the camera offset selected from the <Camera Select> combo box. It can be set up
directly and performing calibration for the camera will input the result value
automatically.
<X> edit box
Set the offset value of the camera in X direction between the center of the each
head and center of the camera.
<Y> edit box
Setup the Y-direction offset value of each head center and the camera center.
<R> edit box
Setup the R-direction offset value of each head center and the camera center.
<Default Light> group
Set the default light value. Please refer to “7.1.1 Common Align Data”for more
information.
<Position Data> group
Set the position of the fix camera.
<X> edit box
Set the X position value of the fix camera.
<Y> edit box
Set the Y position value of the fix camera.
<Ref. Fid. Offset Data> group
Each head has its own reference fiducial mark, which is used to correct the offset.
<Teach> group
Set the position offset of the fix camera.
combo box
Used for moving the selected object to the position of fix camera by rotating XY
axis driving motor, or for obtaining the present coordinates of the fiducial camera
Fid Cam: Selects fiducial camera.
18-12
Fast & Flexible Chip Shooter DECAN F2 Service Manual
<Move> button
Move the object selected in the combo box to the position of the assigned
coordinates. At this time, before executing <Move> button, the fix camera
corresponding to the desired position must be clicked on with a mouse.
<Get> button
Obtain coordinates for XY axis with reference to the object selected in the combo
box. At this time, before executing <Get> button, the fix camera corresponding to
the desired position must be clicked on with a mouse.
<Fiducial Mark …> button
Only fix camera is activated. Used for setting up the position of the fiducial mark of
the fix camera located at the upper part of ANC.
18-13
Machine Calibration
18.3. Calibration [F9]
Only fix camera is activated. Used for setting up the position of the fiducial mark of the fix
camera located at the upper part of ANC.
The following are the works to be performed before performing calibration or those to be
performed in advance.
I/O Test
Mirror offset check and correction
Nozzle check and vacuum check option for system constant
Nozzle check and calibration tool option for system constant : [80] is ‘1’ (default)
ANC type check
Pneumatic system check for any problem
The order in which the calibration is performed and the calibration tool needed to perform
the corresponding calibration is as follows;
Axis Home Calibration
Skew Compensation
Fiducial Camera Scale Calibration - CN400, Calibration Tool
Common X-Y (1st)
Conveyor Calibration
X-XY Compensation – Calibration Bar
Common X-Y (2nd )
Thermal Mapping
Gantry Mapping
ANC Fiducial Mark Teaching
Head & Camera Calibration - CN040, CN400, Light Fly Nozzle, Calibration Tool
Board Position