13-56 Fast & Flexible Chip Shoo ter DECAN F2 Service Manual Pick up 84 Use Fast Pick up Use 1 Const 0: Fast PickUp not used 1: Fast PickUp used 95 Pick T each xy Method Use 0 Const Set th e function for Pick-Up Posit…

100%1 / 604
13-55
Software
R Move 50 Sys Delay R1
Use
50
msec Delay used for general R movement
51 Sys Delay R2
Use
50
msec Delay used for R movement for part pickup
52 Sys Delay R3
Use
15
msec Delay used for R movement for part placement
53 Sys Delay R4
Use
50
msec Delay used for R movement requiring high precision
54 Sys Backlash R
Use
1500
msec Zone used for the R backlash prevention algorithm
Mir Move
55 Sys Delay M1
Use
0
msec In the case of the FLY_SS cycle, this refers to the delay
when the mirror closes.
58 Sys Delay M4
Use
0
msec Delay when the mirror closes
80 Escape M Fast
Use
170000 mdeg
In the case of the FLY_SS Cycle, this refers to the mirror
angle (between 80000 ~ 175000) at which the Z-axis
starts to move when the mirror is opened.
Values other than these will be processed as 8000.
Side
Down
60 Head Side Dn Time
Use
0
msec Minimum time required to operate the side illumination of
the head
61 Head Side Dn
Timeout
Use
500
msec Time-out when operating the side illumination of the head
특정기능
86
Twin Servo Skew Dist
Use
200 um
Allowable skew error of the Y1/Y2
Module No Name Div Value Unit Description
13-56
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Pick up 84 Use Fast Pick up
Use
1
Const 0: Fast PickUp not used
1: Fast PickUp used
95 Pick Teach xy Method
Use
0
Const Set the function for Pick-Up Position XY Offset correction
during automatic placement.
In order to reflect the corrected offset, the No. 31 Debug
Constant (TAPE_PICK_OFFSET_WEIGHT) must be set
to 1.
0: Not used.
1: Performed when Part Retry Out occurs.
2: Corrected immediately before the set Part Retry Out
Count. When it is NG even after the correction, the
machine stops.
3: Always performed before picking up s part (applicable
to fine parts less than 0402).
Module No Name Div Value Unit Description
13-57
Software
13.4. System Constant
Module No Name Div Value Unit Description
Machine 21 Opt Door Open
Use
34
Const D0-D3 : Front Door D4-D7 : Rear Door
>>0:No Check(NO) 1:Low Speed(LOW)
2:Emergency(EMER)
Value: Front, rear
0 :NO, NO
1:LOW, NO
2:EMER, NO
16:NO, LOW
17:LOW, LOW
18:EMER, LOW
32:NO, EMER
33:LOW, EMER
34:EMER, EMER