DECAN_F2_Service(Eng_Ver1).pdf - 第445页

17-33 Troubleshooting  Defective step motor  Interference occurs due to foreign materials on the belt  Defective step motor and pulley  Defective step motor cable [How to Check]  Check the step motor control cable c…

100%1 / 604
17-32
Fast & Flexible Chip Shooter DECAN F2 Service Manual
17.3.5. Errors related to PCB transfer
E0900 When there is no PCB, the system recognizes that there is a PCB or when there is a
PCB, it recognizes that there is no PCB
[Cause]
Defective PCB cable connection
Defective PCB detection sensor connector
The sensor is contaminated with foreign material
[How to Check]
Check whether the sensor cable is cut off
Check whether the PCB detection sensor connector has a problem
Check whether the sensor is contaminated with foreign materials
[Measures]
Replace the sensor cable.
Reassemble the connector of the PCB detection sensor.
Remove foreign materials on the sensor or replace it.
E0901 Unable to transfer the PCB
[Cause]
Cause Description Remarks
PCB jamming When there is no PCB, the system recognizes that there is a
PCB or when there is a PCB, it recognizes that there is no
PCB
E0900
Unable to transfer the PCB E0901
Abnormal PCB transfer E0902
Defective PCB width adjustment – PCB dropped/ PCB
jammed/unable to transfer the PCB
E0903
PCBs are not fed or discharged E0904
The PCB is jammed in the placement range E0905
Abnormal belt tension E0906
Incorrect conveyor parameter setup E0907
A PCB does not stop at the normal position E0908
When transferring PCBs from the previous machine to the
entry station, a PCB is jammed
E0909
Interference occurs while transferring the PCB from the
current machine to the next machine
E090A
After the BUT moved down, the PCB does not move to the
exit station
E090B
17-33
Troubleshooting
Defective step motor
Interference occurs due to foreign materials on the belt
Defective step motor and pulley
Defective step motor cable
[How to Check]
Check the step motor control cable connection. If it has no problems, replace the step
motor and check whether the same problem occurs.
Check whether foreign materials exist on the belt
Move the corresponding belt manually to check for any problems and check whether
the motor and pulley are loosened
Check whether the step motor cable is cut off
[Measures]
Replace the step motor.
Remove foreign materials on the belt.
Replace the step motor and pulley.
Replace the step motor cable.
E0902 Abnormal PCB transfer
[Cause]
The motor cable and connector are defective(The conveyor moves in the reverse
direction)
The output voltage (24V) of the power supply is low(Belt vibration and abnormal belt
movement during PCB transfer)
The cable connected to the step motor driver is not connected properly(Belt vibration
and abnormal belt movement during PCB transfer)
[How to Check]
Check whether the motor power cable and connector have any problems
Check whether the output voltage (24V) of the power supply is normal
Check whether the cable connected to the step motor driver is properly connected
[Measures]
Replace the motor power cable.
Adjust the power supply so that it outputs 24V.
Reconnect the cable connected to the step motor drive properly.
17-34
Fast & Flexible Chip Shooter DECAN F2 Service Manual
E0903 Defective PCB width adjustment – PCB dropped/ PCB jammed/unable to transfer the
PCB
[Cause]
E0903Defective PCB width adjustment – PCB dropped/ PCForeign materials exist on/
around the conveyor axisB jammed/unable to transfer the PCB
The conveyor width margin is not properly set
The conveyor calibration is not performed
[How to Check]
Check for any foreign materials on/around the conveyor axis
Check the conveyor width margin setup
Perform conveyor calibration and check whether the same problem occurs
[Measures]
Remove the foreign materials on/around the conveyor axis and apply grease to it.
Modify the conveyor width margin.
Perform the conveyor calibration.
E0904 PCBs are not fed or discharged
[Cause]
Defective Base Control board
Defective interface connection with other machines and setup
[How to Check]
Check the input state of the 24V power supply of the base control board (LED being
turned on), and after checking the output voltage (24V) of the power supply, replace
the base control board and check whether the same problem occurs.
Check the SMEMA cable to find whether the interface is properly connected with
other machine (24v, )
[Measures]
Replace the Base Control board.
Set the interface signal with machines supplied by other companies again.
E0905 The PCB is jammed in the placement range
[Cause]
The left and right widths of the front and rear frames of the conveyor work zone differ
significantly when adjusting the width
[How to Check]
Check whether the front and rear frames of the conveyor are parallel. Then check
whether the width adjustment axis and conveyor frame form a right angle