17-72
Fast & Flexible Chip Shooter DECAN F2 Service Manual
3. Check the operation of the ANC Shutter solenoid valve.
4. Check the ANC cylinder movement.
5. Check the position and operation of the ANC Cylinder Sensor.
1. Perform manual operation of the ANC.
2. Check for the opening/closing of the ANC shutter.
3. Check the position and operation of the ANC Cylinder Sensor.
1. Perform manual operation of the ANC.
2. Check the ANC fiducial mark position.
Check the nozzle holder visually using a camera.
1. Perform manual operation of the ANC.
3. Check for the opening/closing of the ANC shutter.
4. Check the opening/closing speed of the ANC shutter (controlled with the Speed
Controller)
5. Check the operation of the ANC Shutter solenoid valve.
6. Check the ANC cylinder movement.
7. Check the position and operation of the ANC Cylinder Sensor
[Measures]
Replace the ANC Shutter Cylinder.
Reassemble the ANC Cylinder Sensor.
Teach the ANC fiducial mark again.
Replace the nozzle holder.
Replace the solenoid valve.
After removing and disassembling the cylinder, control the inlet and outlet air flow
rate.
E0E04 Cannot mount a nozzle since there is no nozzle on the head
[Cause]
Vacuum pressure is high (200~350 mmHg when there is no nozzle).
When picking and placing a nozzle, the nozzle body is brightly reflected occasionally
due to the brightness of the outer LED.
Pneumatic pressure becomes high since the filter in the pneumatic line of the head is
assembled in the opposite direction.
There is interference between the opened ANC shutter and nozzle blade.
[How to Check]
1. Check the ANC nozzle setting.

17-73
Troubleshooting
2. Clean and check the vacuum line of the head.
3. Clean the inside of the nozzle.
1. Clean the folding mirror.
2. Clean the Fly Camera lens.
3. Modify the Nozzle Check Setting Data.
1. Check the vacuum pressure.
2. Clean and check the vacuum line of the head.
3. Clean the nozzle.
1. Check the ANC shutter Guide position.
2. Adjust the ANC shutter Guide position.
[Measures]
Clean the air line and replace the filter.
Change the outer brightness of the Nozzle Check setting from 5 to 4.
When assembling the Vacuum Filter, pay attention to the direction.
Reassemble the ANC shutter and cylinder using 4 sets of cylinder bolts so that there
will be no interference between them.
E0E05 When the machine is turned on, feeders feed a part first
[Cause]
The right board of the feeder base is defective.
The feeder I/O board is defective.
The 24V power supply is defective.
The relays #3~#6 are defective.
[How to Check]
1. Check the relay operation of the feeder base board.
2. Replace the feeder I/O board.
3. Replace the feeder base board.
4. Replace the 24V power supply.
[Measures]
Replace the right board of the feeder base.
Replace the feeder I/O board.
Replace the 24V power supply.
Replace or reinstall the relay.

17-74
Fast & Flexible Chip Shooter DECAN F2 Service Manual
E0E06 The feeder is not removed and installed smoothly
[Cause]
Defective machine of the feeder base hole
[How to Check]
1. The feeder is installed and removed stiffly.
2. Check the external shape of the feeder.
3. Replace the feeder base.
[Measures]
Replace the feeder base.
E0E07 Failed to move up the front docking cart
[Cause]
The D-CART Probe Pin is damaged.
[How to Check]
Replace the D-CART Inner I/F cable assembly.
[Measures]
Replace the D-CART Inner I/F cable assembly.
E0E08 Only one part in the vibration feeder is continuously picked up
[Cause]
The feeder is used with its link function being cleared.
[How to Check]
Set the ‘Successive Link’ function of the ‘Stick Auto Link Opt’ in the system.
[Measures]
Set the ‘Successive Link’ function of the ‘Stick Auto Link Opt’ in the system.
E0E09 The [Open Error] of the Feeder Part $P Clamp is cleared. (Vibration feeder Index is
defective)
[Cause]
The white pin is disconnected (disconnected inside the shield).
[How to Check]
1. Check the operation of the vibration feeder.
2. Check the probe pin of the vibration feeder.
3. Check the inner board and connector of the vibration feeder.
[Measures]
Solder and connect the disconnected pin.