Fast & Flexible Chip Shooter DECAN F2 Service Manual
Click the <Next> button to move down the Z-axis of the head in order to manually
move all nozzles inserted in the nozzle-holder of the head.
4. Then, after the head assembly moves to the designated position, move all Z-axes
down. At this time, remove all inserted nozzles manually.
5. “The message “Move To Center Position of Calibration Tool. To Move, Click [Next].”
appears in the message window. Click the <Next> button to move the head assembly
to the calibration tool position on the ANC.
6. The message “Move To Center Position of [Fix1] Camera. To Move, Click [Next]”
appears. Click the <Next> button to move the head assembly to the center of the Fix1-
Camera. At this time, select the ‘Fix Cam1’ in the <Target Camera> combo box. Click
the <Light…> button and adjust the brightness of the light in the ‘Light Control’
dialog box so that the fiducial mark on the CN400 nozzle that is seen in the
‘SMVision’ window can be seen clearly.
7. Then the Head 1 moves up to the ‘part-alignment height’ of the fly camera and the
mirror is closed.
Then the message “Calibration is Prepared. To Calibrate, Click [Next]” appears in the
message window. At this time, click the <Light…> button and adjust the brightness of
the light in the ‘Light Control’ dialog box so that the fiducial mark on the calibration
tool that is seen in the ‘SMVision’ window can be seen clearly. Then click the <Next>
button.
8. In order to perform calibration, first recognize the 2 fiducial marks on the bottom
surface of the calibration tool by using the fly camera while rotating the calibration
tool at 45 degree intervals.
Then put the calibration tool down on the calibration tool position on the ANC and
recognize the 2 fiducial marks on the top surface of the calibration tool by using the
fiducial camera.
Subsequent to that, pick the calibration tool again, rotate it by 90 degrees and put it
18-75
Machine Calibration
down at that spot. Then recognize the 2 fiducial marks on the upper surface of the
calibration tool by using the fiducial camera.
In this manner, rotate each head at 90 degree intervals and perform measurement in
four directions of 0, 90, 180 and 270 degrees.
9. If the calibration procedure is completed for all heads normally, the result is displayed
as shown in the following figure.
10. .From Head #2 to Head #10, perform calibration in the same manner as it was
performed for Head #1.If the calibration procedure is completed for all heads
normally, the result is displayed as shown in the following figure.
18-76
Fast & Flexible Chip Shooter DECAN F2 Service Manual
11. .Select Gantry 2 in the <Gantry> combo box and perform calibration in the same
manner as has been done for Gantry 1.
The measurement result can be confirmed in the Fly-Fix Offset dialog box
Memo The reference values for the calibration of the Fly to Fix Offset is as
follows.
Offset X : -0.050 ~ 0.050(mm)
Offset Y : -0.050 ~ 0.050(mm)
The reference values for the calibration of the Fly to Fix Offset is as
follows.
Offset X : -0.020 ~ 0.020(mm)
Offset Y : -0.020 ~ 0.020(mm)