17-23 Troubleshooting Check whether the MMI versions of the machines in the line are same [Measures] Maintain the MMI SW version of the ma chines in the same line to be identical. E0717 The buzzer sounds continuously…

17-22
Fast & Flexible Chip Shooter DECAN F2 Service Manual
E0713 Warning that the camera is not installed. CAM:2 …
[Cause]
The MMI system file is damaged.
[How to Check]
Check the camera setup in the Camera submenu of the Sys.Setup menu.
[Measures]
Reinstall the MMI software.
E0714 The DLL file cannot be found while executing the MMI
[Cause]
The MMI system file is damaged
Infected by a virus
[How to Check]
Perform HDD recovery and reinstall the MMI. Then check whether the same problem
occurs
Temporarily install an anti-virus program and check whether the file was infected by a
virus. (Delete the temporarily installed anti-virus program after inspection.)
[Measures]
Perform HDD recovery and reinstall the MMI.
If it is confirmed that the file was infected by a virus, remove the virus and then delete
the anti-virus program. If a problem occurs after booting or the system malfunctions,
perform HDD recovery
E015 When opening a file, even though the file name exists, the file is not opened
[Cause]
The MMI or Windows system file is damaged
[How to Check]
Perform a virus check of the HDD to check whether it has been infected. Format the
HDD and perform HDD recovery. Then reinstall the MMI and check whether the same
problem occurs
[Measures]
Format and recover the HDD and then reinstall the MMI.
E0716 When opening the PCB file, the PCB file in a certain folder was not opened
[Cause]
The PCB file created in the higher MMI version is opened in the lower version
[How to Check]

17-23
Troubleshooting
Check whether the MMI versions of the machines in the line are same
[Measures]
Maintain the MMI SW version of the machines in the same line to be identical.
E0717 The buzzer sounds continuously with the MMI being closed after a message was
generated during operation
[Cause]
Infected by a virus
[How to Check]
Perform a virus check of the HDD to check whether it has been infected. Format the
HDD and perform HDD recovery. Then reinstall the MMI and check whether the same
problem occurs
[Measures]
After removing the memory of the SBC board, insert it again, and insert the SBC
board into the vision board connector properly.
Then insert the vision board into the back plane board slot and after booting it,
perform a virus check to determine whether it is infected by a virus. After formatting
the HDD, perform HDD recovery and reinstall the MMI.
E0718 When booting the machine, the login password input window is displayed. When a
password is inputted, the ‘Incorrect Password’ message is indicated and Windows is
not booted
[Cause]
The Windows booting file is infected by a virus
[How to Check]
Perform a virus check of the HDD to check whether it has been infected. Format the
HDD and perform HDD recovery. Then reinstall the MMI and check whether the same
problem occurs
[Measures]
Format and recover the HDD and then reinstall the MMI.
E0719 If the tape feeder is set to ‘None’, the tape feeder is set at the slot below it
[Cause]
Infected by a virus
[How to Check]
Perform a virus check of the HDD to check whether it has been infected. Format the
HDD and perform HDD recovery. Then reinstall the MMI and check whether the same
problem occurs

17-24
Fast & Flexible Chip Shooter DECAN F2 Service Manual
[Measures]
Perform HDD recovery and install the operating system and MMI.
E071A An error indicating the skip count occurred in the Steps dialog box
[Cause]
The filtering function is used in the ‘Step’ dialog box
[How to Check]
Check whether the filtering function is applied in the ‘Step’ dialog box
[Measures]
Release the filtering function and check the skipped part.
E071B Failed to pick up 0603 chips simultaneously
[Cause]
The feeder position is not set correctly or the System Factory Constant is set
incorrectly.
[How to Check]
After checking whether the feeder position is set correctly, check whether the No. 73
item of the System Factory Constants is ‘250’.
[Measures]
Modify the factory constant for the simultaneous pickup of 0603 chips. (No. 73 VERY
SMALL COMPSIZE: 380 250)
E071C Head# Dump Limit Error
[Cause]
The dump box position is set to the position where all heads cannot access
[How to Check]
Check the dump box position setup of the system to check whether it is at a position
where all heads can access it
[Measures]
Add and use new dump box at a position where all heads can access it.
E071D An error occurred while dumping the connector
[Cause]
The connector length is longer than the dump box width
[How to Check]
Check whether the part dump angle is correct and check that the dump box width is
longer than the connector length