18-19 Machine Calibration First, move the X frame manually to the center of equipment. Click on the <Skew compensation> button. Automatic homing on Z-ax is is performed, Y1-axis motor rotates and mo ves X frame…

18-18
Fast & Flexible Chip Shooter DECAN F2 Service Manual
<Update> button
Transmits the set data to the machine and closes the dialog box.
<Close> button
Ignores the set data and closes the dialog box.
Caution If calibration is done again, the machine might not operate
properly unless the items related to the equipment position,
such as pick up position, ANC, placement origin are taught
again as the home position is changed.
After calibration, be sure to teach the items related to
position again.
18.3.2. Skew compensation
Skew means compensating the skew occurred horizontally in the X-axis frame against the
Y1-axis and Y2-axis after movement of equipment. This must be done upon initial
installation and after movement of the equipment to a new location. Method of skew
compensation for Y-axis is as follows;
Caution Skew means compensating the skew occurred horizontally
in the X-axis frame against the Y1-axis and Y2-axis after
movement of equipment. This must be done upon initial
installation and after movement of the equipment to a new
location. Method of skew compensation for Y-axis is as
follows;

18-19
Machine Calibration
First, move the X frame manually to the center of equipment.
Click on the <Skew compensation> button. Automatic homing on Z-axis is performed,
Y1-axis motor rotates and moves X frame until detecting the Y home sensor. Once the
home sensor has been detected, move to the Y-axis movement distance (Y Stroke) in
the opposite direction, and move to the opposite direction again until the Y Home
sensor is detected.
Then, ‘Skew’ information is shown as follows, and asks whether to apply the value.
Click on the <Yes (Y)> button and <Update> button, and then homing of the
equipment is newly done in accordance with the applied skew information.

18-20
Fast & Flexible Chip Shooter DECAN F2 Service Manual
18.3.3. Fiducial Camera Scale
In the case of the DECAN G2 model, since it has no fix camera, in most cases the
calibration must be performed by using the fiducial camera. Therefore, the scale
calibration of the fiducial camera must be performed first.
If the fiducial camera is not calibrated, the rest of the buttons are disabled.
<1. Fid. Scale Mark Position> button
Set the position of the reference fiducial mark located at the top surface of the ANC.
When performing the scale calibration of the fiducial camera by using the calibration
tool, place the calibration tool at the position for the calibration tool on the front ANC.