DECAN_F2_Service(Eng_Ver1).pdf - 第328页

13- 58 Fast & Flexible Chip Shoo ter DECAN F2 Service Manual To w e r Lamp 4 Opt Sig T ype Use 0 Const T ypes of tower lamps (used in the MMI) 5 Opt Sig Red Use 21 12 Const Setu p for the tower lamp operation 6 Opt S…

100%1 / 604
13-57
Software
13.4. System Constant
Module No Name Div Value Unit Description
Machine 21 Opt Door Open
Use
34
Const D0-D3 : Front Door D4-D7 : Rear Door
>>0:No Check(NO) 1:Low Speed(LOW)
2:Emergency(EMER)
Value: Front, rear
0 :NO, NO
1:LOW, NO
2:EMER, NO
16:NO, LOW
17:LOW, LOW
18:EMER, LOW
32:NO, EMER
33:LOW, EMER
34:EMER, EMER
13-58
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Tow er
Lamp
4 Opt Sig Type
Use
0
Const Types of tower lamps (used in the MMI)
5 Opt Sig Red
Use
2112
Const Setup for the tower lamp operation
6 Opt Sig Yel
Use
257
Const D0-D1: IDLE
D2-D3: RUN
D4-D5: PAUSE
7 Opt Sig Grn
Use
292
Const D6-D7: FREEZE
D8-D9: ADJUST
D10-D11: EMER
8 Opt Sig Blue
Use
0
Const 0: ACT_OFF
1 : ACT_ON
2 : ACT_BLINK
Module No Name Div Value Unit Description
13-59
Software
Tow er
Lamp
9 Opt Sig Part Empty
Use
5
Const Used with a combination of the following setups:
1: Part Empty Warning (Yellow/Blue)
2: Part Empty Error (Red)
4: PCB Wait Warring (Yellow/Blue)
8: Bypass (Safe Guard) Warring (Yellow/Blue)
15 Opt Buzon off
Use
2
Const 0: Always Buzzer On when an error occurs
1: Always Buzzer Not On when an error occurs
2: Buzzer On selectively when an error occurs
61 Opt PCB Wait
Warning Time
Use
20
Const When waiting for a PCB in the Run state, change the
tower lamp signal after the given period of time
(according to the No. 9 system constant setup).
Module No Name Div Value Unit Description