DECAN_F2_Service(Eng_Ver1).pdf - 第526页
18-6 Fast & Flexible Chip Shooter DECAN F2 Service Manual <Device> combo box Select the head. <Use Compensation> check box Determines whether to use the R axis compensation method for each head. <…

18-5
Machine Calibration
<Y> column
Sets the Y offset value. Set the Y position of the head1 to 0 when the XY axes
reach and set this value as a reference.
<Z> column
Sets the Z offset value. Set the PCB top surface as the reference of the offset value
when the PCB is loaded.
<R> column
Sets the R offset.
<Other Device> group
Sets the offset values of devices other than the head.
<Fiducial Cam> edit box
Sets the XY offset value of the Fiducial camera.
18.1.3. <R Axis> tab dialog
Displays the R axis compensation value of each head, or determines whether to
compensate the R axis. Data in this dialog box is updated automatically if the R-Axis
Offset Calibration is executed during camera calibration and the result value is reflected.
Setup whether to apply compensation on the R-axis of each head or not.
Figure18.3 “R AXIS” tab dialog
<Check Data> group
Indicates the R axis compensation value of each head.

18-6
Fast & Flexible Chip Shooter DECAN F2 Service Manual
<Device> combo box
Select the head.
<Use Compensation> check box
Determines whether to use the R axis compensation method for each head.
<Real Max R> edit box
Indicates the maximum error of the actual value of R axis to its abnormal value.
<Real Min R> edit box
Indicates the minimum error of the actual value of R axis to its abnormal value.
<Err Max> edit box
Indicates the maximum error of the compensation value for the actual value of the
R axis.
<Err Min> edit box
Indicates the minimum error of the compensation value for the actual value of the
R axis.
<Update> button
Transmits the change data to the equipment and closes the dialog box.
<Cancel> button
Ignores the change data and closes the dialog box.

18-7
Machine Calibration
18.1.4. <Fly-Fix Offset> tab dialog
Sets the Fly-Fix offset for each head. Data in this dialog box is updated automatically if the
Fly to Fix Offset Calibration is executed during camera calibration and the result value is
reflected.
Figure18.4 “Fly-Fix Offset” tab dialog
<Device> combo box
Sets the Fly-Fix offset for each head.
<Fly To Fix Offset>
<Degree> column
Sets the Fly-Fix offset by degree at 45 degree interval.
<X, Y> column
Sets the Fly-Fix offset of X, Y.
<Fly Run Out Offset>
<Degree> column
Fly-Fix offset for each angle can be setup at the interval of 45 degrees.
<X, Y> column
Sets the Fly Run Out offset of X, Y.
<Clear data for this Head> button
Deletes Fly-Fix offset data of the selected head. Used when not applying the Fly-Fix
offset on the head. Data cannot be restored once it has been deleted. To apply the Fly-
Fix offset, the camera calibration must be performed again.
<Update> button