13-64 Fast & Flexible Chip Shoo ter DECAN F2 Service Manual Docking 63 Opt DC Safety Use 4 Const It is possible to check the sensors related to docking cart safety by option: 0: All safety sensors checked 1: Left/rig…

13-63
Software
편의사항
25
Opt Home Method
Use
15
Const 1: Not performed newly if XY homing is performed before
during actual placement
2 : Not performed newly if Z homing is performed before
actual placement
4 : Not performed newly if R homing is performed before
actual placement
8 : Not performed newly if MIR homing is performed
during actual placement
16 : Not performed newly if BUT homing is performed
before actual placement
33
Opt Lts Method
Use
0
0: Not used
1: Used
41
Opt Light Saver Time
Out
Use
300
Const Refers to the function that turns off all illuminations after
the time set here to protect the illumination
Conveyor 19 Opt Quicklload
Use
1
Const 1: Quick Work->Use of Out Sensor
16: Sync Move (Quick Load previous)
99 CV Config User Sel
Use
1
Const 0: CV Not selected
1: CV Selected
Module No Name Div Value Unit Description

13-64
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Docking 63 Opt DC Safety
Use
4
Const It is possible to check the sensors related to docking cart
safety by option:
0: All safety sensors checked
1: Left/right docking detection sensor check cleared
2: Door open state check cleared
4: Docking cart cable connection state check cleared
Mir 32 Opt Use Mir Safety
Use
0
Const Currently set so that it will not change according to the
value.
0 : Not used
1 : Used only for homing
ANC 34 Opt NZ Vis Chk
Use
0
Const Check whether there is a nozzle in the ANC pocket
before placing the nozzle:
0: Not Checked
1: checked
64 Opt ANC Shutter
Use
50
Const Use the function minimizing the ANC shutter Open/Close
movement when getting a nozzle
0: Not Checked
1: checked
Module No Name Div Value Unit Description

13-65
Software
Vacuum 60 Opt Vac Dump Saver
Time Out
Use
300 sec
When the head vacuum is not used in the IDLE mode,
shut off the vacuum pump after a given period of time.
66 Opt Pick Vac Chk
Use
19
msec 0: The routine to check whether the part is picked up is
not used when picking up a part
1: The routine to check whether the part is picked up is
used when picking up a part
safety 47 Opt Area Sensor
Use
0
Const 0: Not Checked
1: Area Sensor used
Align /
Mount
50 Opt MFOV No Z Up
Use
0
Const 0: The Z-axis moves up/down during XY movement for
split recognition
1: The Z-axis does not move during XY movement for
split recognition
71 Opt HRS Vision
Use
0
Const 0: HRS function not used
1: HRS function used
Module No Name Div Value Unit Description