Memo The range of the reference value for the ‘head offset calibration’ are
as follows:
Head 1
X:-0.06mm~0.06mm, Y: -0.05mm~0.05mm
Head 2
X:14.94mm~15.06mm, Y: -0.05mm~0.05mm
Head 3
X:29.94mm~30.06mm, Y: -0.05mm~0.05mm
Head 4
X:44.94mm~45.06mm, Y: -0.05mm~0.05mm
Head 5
X:59.94mm~60.06mm, Y: -0.05mm~0.05mm
Head 6
X:74.94mm~75.06mm, Y: -0.05mm~0.05mm
Head 7
X:89.94mm~90.06mm, Y: -0.05mm~0.05mm
Head 8
X:104.94mm~105.06mm, Y: -0.05mm~0.05mm
Head 9
X:119.94mm~120.06mm, Y: -0.05mm~0.05mm
Head 10
X:134.94mm~135.06mm, Y: -0.05mm~0.05mm
18-65
Machine Calibration
Head 11
X:-0.06mm~0.06mm, Y: -0.05mm~0.05mm
Head 12
X:-15.06mm~-14.94mm, Y: -0.05mm~0.05mm
Head 13
X:-30.06mm~-29.94mm, Y: -0.05mm~0.05mm
Head 14
X:-45.06mm~-44.94mm, Y: -0.05mm~0.05mm
Head 15
X:-60.06mm~-59.94mm, Y: -0.05mm~0.05mm
Head 16
X:-75.06mm~-74.94mm, Y: -0.05mm~0.05mm
Head 17
X:-90.06mm~-89.94mm, Y: -0.05mm~0.05mm
Head 18
X:-105.06mm~-104.94mm, Y: -0.05mm~0.05mm
Head 19
X:-120.06mm~-119.94mm, Y: -0.05mm~0.05mm
Head 20
X:-135.06mm~-134.94mm, Y: -0.05mm~0.05mm
18.3.10.5. Fly Camera Scale Calibration
This calibration is performed to find the scale and rotation offset of the fly-camera. In
order to calibrate the scale and rotation of the fly-camera, the ‘fix-camera calibration’ and
‘head Z-offset calibration’ must be performed in advance and the CN400 Nozzle must be
used.
The following is the procedure to calibrate the ‘Fly-Camera Scale Calibration’
1. Click the <Nozzle Prepare> button and insert the CN400 nozzle into the No. 1 hole of
the ANC manually.
If the <10 Fly Camera Scale> is clicked after selecting the <Automatic Next> check
box, calibration is performed for the selected gantry automatically.
If calibration is performed after selecting the <No Real Motion [Manual]> check box,
the nozzle is inserted into each head manually. Click the <Next> button to move onto
the next step.
18-66
Fast & Flexible Chip Shooter DECAN F2 Service Manual
If calibration is performed without selecting either the <Automatic> check box or
<Manual> check box, the nozzle is changed automatically for the currently selected
nozzle. Click the <Next> button to move onto the next step.
2. If the <10. Fly Camera Scale> button is clicked, the message box “First, We must Put
all Nozzles From Heads on Manually. To Move down Z Axis, Click [Next]” appears in
the message box. Click the <Next> button to move down the Z axis of the head in
order to remove all nozzles inserted in the nozzle-holder of the head manually.
3. Then, after the head assembly moves to the designated position, move all Z-axes
down. At this time, remove all inserted nozzles manually.
4. Then the message “Next Attach the Calibration Tool to Head 1. Click [Next] for
Moving Down Head. After Moving, Attach the Tool to head Manually” appears. Click
the <Next> button after inserting the CN400 nozzle in the nozzle-holder of Head #1
manually.
5. The message “Move To Center Position of Calibration Tool. To Move, Click [Next].”
appears in the message window. Click the <Next> button to move the head assembly
to the calibration tool position on the ANC.
6. Then the message “Align Tool for Calibration! Then Click [Next]” appears. Click the
<Next> button.
7. Then the message “Up to Align Height and Mirror Close, Click [Next]” appears. Click
the <Next> button.
8. Then, the Head1 Pick the Calibration Tool and Z-axis of the Head 1 moves up to the
‘part-alignment height’ of the fly camera and the mirror is closed. and the message
“Calibration is Prepared. To Calibrate, Click [Next]” appears in the message box. At
this time, select the ‘Fly1 Cam’ in the <Target Camera> combo box. Click the
<Light…> button and adjust the brightness of the light in the ‘Light Control’ dialog