DECAN_F2_Service(Eng_Ver1).pdf - 第418页

17-6 Fast & Flexible Chip Shooter DECAN F2 Service Manual  Perform HDD recovery and reinstall the MMI.  Replace and rec over the HDD and then reinstall the MMI.  Remove the memory of the SBC bo ard and insert it a…

100%1 / 604
17-5
Troubleshooting
[How to Check]
Check the Windows error information and check whether a bad sector occurred to the
HDD
Check for virus infection using an anti-virus program
Replace the SBC board and check whether the PC is booted properly
Access the CMOS Setup screen to check whether the HDD is recognized properly
Replace the SBC board and CPU to check whether the PC is booted properly
Replace the vision board and COM-VM sub-board and check whether they are booted
properly
Check whether the SBC board is inserted into the vision board connector properly
Check whether the site temperature is higher than 24? and then check whether the
HDD is recognized properly
[Measures]
Replace and recover the HDD and then reinstall the MMI.
Perform virus treatment and install HDD Recovery software.
Replace the SBC board.
Replace the SBC board and HDD, perform HDD recovery and reinstall the MMI.
Replace the SBC board.
Replace the vision board or COM-VM sub-board.
Remove the SBC board and insert it into the vision board connector properly.
Remove the slot cover and discharge the heat inside the PC rack and then reboot the
PC.
E0502 The PC stops when it almost starts Windows while booting the PC
[Cause]
The ‘Initializing and establishing link …’ error occurred in the DOS mode
Defective HDD
The memory of the SBC board is not inserted properly
Defective SBC board
[How to Check]
Check for the occurrence of the ‘Initializing and establishing link’ error
Access the CMOS Setup screen to check whether the HDD is recognized properly
Check whether the memory of the SBC board is inserted properly
Replace the SBC board and check whether the PC is booted properly
[Measures]
17-6
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Perform HDD recovery and reinstall the MMI.
Replace and recover the HDD and then reinstall the MMI.
Remove the memory of the SBC board and insert it again properly.
Replace the SBC board.
17.3.2. Failed to initialize the MMI and unable to execute it
E0600 The [Grabber type does not match...], [fail to run visframe] and [Run Time Error]
error occurred during VisFrame initialization while loading the MMI.
[Cause]
Defective SBC board
The vision image file is infected by a virus
When the control rack contact is defective (SBC, Vision, RT CPU, NCIO, ZMP) /
SBC board is not connected to the vision board connector / Vision board, RT board
and ZMP board are not inserted into the back plane slot properly
The MMI file is damaged
The back plane board is not properly inserted into the board
The VisFrame initialization failed since the time at which the vision error occurred is
different from the Windows XP time due to defective Windows XP time setup
The vision board, RT board, NCIO board and ZMP board are not recognized due to a
defective back plane board
Cause Description Remarks
Defective
initialization
The [Grabber type does not match...], [fail to run visframe]
and [Run Time Error] error occurred to the Initializing
visframe while loading the MMI
E0600
The MMI does not operate and the PC has been shut down
(occurred during MMI operation)
E0601
When booting the PC after shutdown, it is repeatedly
rebooted
E0602
The processing speed of the PC is slow with a pause during
processing
E0603
An Initializing Machine I/F error occurred while loading the
MMI
E0604
An MFC related arithmetic operation error occurred while
booting the MMI (system file not found)
E0605
Defective MMI booting (assert failure occurred) E0606
A Windows system error occurred while loading the MMI
(forced exit)
E0607
17-7
Troubleshooting
Defective NCIO board (only for the Excen machine)
Defective base control board (only for the Excen machine)
[How to Check]
Replace the SBC board and check whether the MMI is properly executed
Check whether the image in the ErrorVisFile of the D drive has no problem
After checking whether the SBC board is properly connected to the vision board
connector, check whether the vision board, RT board, NCIO board and ZMP board are
properly inserted into the back plane slot
Reinstall the MMI and check whether the same problem occurs
Check whether the Windows XP time setup is correct
Replace the back plane board and check whether the MMI is properly executed
Replace the NCIO master board and check whether the MMI is properly executed
Replace the Base Control board and check whether the MMI is properly executed
[Measures]
Replace the SBC board.
Delete the image on which the saving date is not indicated and perform a virus check
periodically.
Check whether the CPU module is properly inserted into the SBC board; whether the
SBC board is properly connected to the vision board connector; and whether the vision
board, RT board, NCIO board and ZMP board are properly inserted into the back
plane board.
Reinstall the MMI.
Check whether a back plane pin is bent and insert the vision, RT, NCIO and ZMP
boards properly again.
Change the Windows O/S or delete the folder in which vision error images are saved.
Replace the back plane.
Replace the NCIO master board.
Replace the Base Control board.
E0601 The MMI does not operate and the PC has been shut down (occurred during MMI
operation)
[Cause]
The program runs slowly and the PC is shut down due to an overheated CPU as the PC
rack cooling fan does not operate
Defective SBC board
The Windows system file is damaged