DECAN_F2_Service(Eng_Ver1).pdf - 第573页
18-53 Machine Calibration 6. Rotate the spindle in the R-direction by us ing the teaching box so that the shape of the nozzle holder becomes ‘( )’. At this time, the nozzle holders of the heads with interlocked mechanism…

18-52
Fast & Flexible Chip Shooter DECAN F2 Service Manual
3. Then the message “Please Check and Register Nozzle CNT0 to ANC 1-2 Hole. First,
We must Put all Nozzles from Heads manually. To Moving Down Z Axis, Click
[Next]” appears in the message window.Remove all nozzles inserted in the nozzle-
holder manually by clicking the <Next> button. At this time, for the ANC, the virtual
nozzle CNT0 is set for the No. 1 hole of the ANC and it is regarded that the
corresponding head picked the CNT0 nozzle.
4. Then the message “Up to Align Height and Mirror Close. To Move, Click [Next].”
appears. Then move the spindle to the part recognition height so that the nozzle holder
of the head can be seen from the fly camera and click the <Next> button to close the
mirror.
5. Execute the ‘Current Position’ dialog box by clicking the shortcut menu.

18-53
Machine Calibration
6. Rotate the spindle in the R-direction by using the teaching box so that the shape of the
nozzle holder becomes ‘( )’. At this time, the nozzle holders of the heads with
interlocked mechanism must be assembled in the same direction.
That is, the mechanisms of the #1~#2 heads and #3~#4 heads, #5~#6 heads, #7~#8
heads, #9~#10 heads must be assembled first in the same direction by using the jig for
a nozzle holder.
7. At this time, input the current position value of the R-axis and click the <Update>
button.

18-54
Fast & Flexible Chip Shooter DECAN F2 Service Manual
8. Perform the calibration form Head 2 to Head 10 in the same manner.
9. Click the <Update> button to apply the calibration result to the machine.