Machine Calibration
18.3.10.3. Light Mapping
Calibrate the brightness of the light for the camera. In order to perform this calibration,
insert the LightFix into the No. 1 nozzle of the ANC.
Caution Since the nozzle for the SM32x,SM411, SM421 model is
not compatible to the one for the light mapping used for the
SM32x,SM411, SM421 model, do not use it for this
machine.
1: Light Level group
<Select Camera> combo box
Selection Control
Select the camera to perform light mapping.
Light Level group
Sets the brightness by light level.
<Level> column
Dislays 16 steps of lighting.
<Side>/ <Outer>/ <Coaxial> column
For the Fly Camera: Input the side illumination value within the range of 256
values.
For the Fix Camera: Input the side illumination value within the range of 4096
18-56
Fast & Flexible Chip Shooter DECAN F2 Service Manual
values.
<Mapping/Test> button
Perform test or automatic mapping for the light level for the camera selected from the
<Select Camera> group.
Figure18.16When the Fiducial Camera is selected
Figure18.17When the Fly Camera is selected
<1. Test Area> group
Designates the area for which the nozzle for test checks the brightness of the
lighting. The are can be designated up to 4. the search area and excluded area are
18-57
Machine Calibration
designated together. That is, the area is designated in the form of circle band.
There are a total of 4 areas, among which Area 1 ~ Area 4 are corresponding areas.
Do not change the value since it is set automatically.
[Bottom Shape of Calibration Nozzle for Small-Fix Camera]
Test Area1 =Search Area(A) –Excluded Area (B +C)
Test Area2 =Search Area(B) –Excluded Area (C)
Test Area3 =Search Area(C)
Test Area4 =Test Area1 +Test Area2 +Test Area3
There are a total of 3 areas, among which Area 1 ~ Area 3 are corresponding areas.
[Bottom shape of the calibration nozzle for the fid camera]
Test Area1 =Search Area(A) –Excluded Area (B)
Test Area2 =Search Area(B)
Test Area3 =Test Area1 +Test Area2
<No> column
Displays the serial number of the test are.
<Pos X> column
Displays the X coordinate of the area center.
<Pos Y> column
Displays the Y coordinate of the area center.
<Size X> column
Displays the area size in the X direction.
<Size Y> column
Displays the area size in the Y direction.
<Type> column
Designates the shape of the area.