3-19 Installation & Operation 3.2.2. Checking System I/O 1) Select the ‘Diagnosis’ menu in the menu and select submenu ‘I/O’ 2) The <Output S tatus> group at the left of the ‘I/O S tatus’ dialog box indicates t…

3-18
Fast & Flexible Chip Shooter DECAN F2 Service Manual
6) Push the PCB slowly and adjust the conveyor until when the PCB flows smoothly
while passing the PCBs.
3.2. Commissioning
3.2.1. Checking Motor I/O
1) Checking Motor I/O1.Before turning on the main circuit breaker, check if there is any
element in the conveyor or inside the machine, which may cause problem.
2) If arrangement around the machine is finished, turn on the main switch to supply
power to the machine. At this time, check whether the front emergency switch is
released and then the front door is closed.
Caution If the power supply and internal of the machine are not
checked before turning on the main switch, the machine
may be damaged or personal injury may occur. Be sure to
check inside and outside of the machine before turning on
the main switch.
3) Once the MMI program is loaded, check the I/O of the XY motor with ‘Ready’ switch
on the front OP panel not pressed. Check if the +/- limit sensor and home sensor
operate normally for the XY motor by sensing the sensors manually. In this case, the
XY axis can be moved easily by hand.

3-19
Installation & Operation
3.2.2. Checking System I/O
1) Select the ‘Diagnosis’ menu in the menu and select submenu ‘I/O’
2) The <Output Status> group at the left of the ‘I/O Status’ dialog box indicates the
machine output.
3) Clicking the list in the <Sensor (Input) Status> group at the right of the ‘I/O Status’
dialog box will turn on/off the input of the corresponding machine and check the input
and output.

3-20
Fast & Flexible Chip Shooter DECAN F2 Service Manual
3.2.3. Communication Interface Setup between Machines
1) Set the communication interface between the Previous Machine and Next Machine by
referring to the following.
1: Next Machine
2: Previous Machine
START Input Signal (Cable No.:?(+),?(-))
The input signal is outputted from the next machine and voltage of approximately
20 ~ 22V is measured at most input signal terminals.
READY Output Signal (Cable No.:? , ?)
The output signal is outputted to the previous machine. Generally, at most output
signal terminals, 0 is measured when output signal is outputted and is
measured when output signal is not outputted.
If the I/F connectors of neighboring machines are different, cut the cable and connect
it referring to the following figure.