DECAN_F2_Service(Eng_Ver1).pdf - 第423页

17-11 Troubleshooting  Replace the Base Control board and check whether the same proble m occurs  Check whether the output voltage (24V) of the PC power supply is normal  Replace the ba ck plane board and ch eck wheth…

100%1 / 604
17-10
Fast & Flexible Chip Shooter DECAN F2 Service Manual
[How to Check]
Perform HDD recovery and reinstall the MMI. Then check whether the same problem
occurs
Replace the SBC board and perform HDD recovery. Reinstall the MMI and check
whether the same problem occurs
Check for virus infection using an anti-virus program
Perform HDD recovery and reinstall the MMI. Then check whether the same problem
occurs
Replace the SBC board and check whether the same problem occurs
[Measures]
Perform HDD recovery and reinstall the MMI.
Replace the SBC board and perform recovery and then reinstall the MMI.
Eliminate the virus using an anti-virus program.
Replace the HDD and perform its recovery and then reinstall the MMI.
Replace the SBC board.
Connect the HDD data cable directly to the SBC board.
E0604 The Initializing Machine I/F error occurred while loading the MMI
[Cause]
Defective SBC board
Microsoft Visual C++ Runtime Library Error
Vision, ZMP and NCIO boards are not properly inserted into the back plane board.
Defective contact of vision, ZMP and NCIO boards.
The MMI system file is damaged due to forced exit
The Base Control board is defective
Abnormal output (24V) of the PC power supply
Defective back plane board
Defective vision board
[How to Check]
Check whether the CPU cooling fan operates properly. If it has no problems, replace
the SBC board and check whether the same problem occurs
Remove the SBC board from the vision board and then insert it again. Remove the
vision, NCIO and ZMP boards from the back plane board slot. Then insert it properly
and check whether the same problem occurs
Check whether a bad sector has occurred through HDD inspection. If it has no
problem, reinstall the MMI and check whether the same problem occurs
17-11
Troubleshooting
Replace the Base Control board and check whether the same problem occurs
Check whether the output voltage (24V) of the PC power supply is normal
Replace the back plane board and check whether the same problem occurs
Replace the vision board and check whether the same problem occurs
[Measures]
Replace the CPU cooling fan and SBC board.
Remove the SBC board from the vision board and then insert it again. Remove the
vision, NCIO and ZMP boards from the back plane board slot. Then insert it again
properly.
Check whether a bad sector has occurred through HDD inspection. If it has no
problem, reinstall the MMI.
Replace Base Control board.
Replace the power supply unit
Replace the back plane board.
Replace the vision board.
E0605 An MFC related arithmetic operation error occurred while booting the MMI (system
file not found)
[Cause]
A problem occurred to the MMI or Windows O/S
[How to Check]
Perform HDD recovery and reinstall the MMI. Then check whether the same problem
occurs
[Measures]
Perform HDD recovery and reinstall the MMI.
E0606 Defective MMI booting (assert failure occurred)
[Cause]
The Windows system file is damaged
The SBC board is not properly connected to the vision board connector or the vision
board is not properly inserted into the back plane slot (defective SBC board contact)
[How to Check]
Perform HDD recovery and reinstall the MMI. Then check whether the same problem
occurs
Remove the SBC board from the vision board connector and insert it again. Then
remove the vision board from the back plane board slot and insert it again properly and
then check whether the same problem occurs
17-12
Fast & Flexible Chip Shooter DECAN F2 Service Manual
[Measures]
Perform HDD recovery and reinstall the MMI.
Remove the SBC board from the vision board connector and insert it again. Then
remove the vision board from the back plane board slot and insert it again properly.
E0607 Windows system error occurred while loading the MMI (forced exit)
[Cause]
The Windows system file is damaged
The SBC board is not properly connected to the vision board connector or the vision
board is not properly inserted into the back plane slot (defective SBC board contact)
[How to Check]
Perform HDD recovery and reinstall the MMI. Then check whether the same problem
occurs
Remove the SBC board from the vision board connector and insert it again. Then
remove the vision board from the back plane board slot and insert it again properly and
then check whether the same problem occurs continuously
[Measures]
Perform HDD recovery and reinstall the MMI.
Remove the SBC board from the vision board connector and insert it again. Then
remove the vision board from the back plane board slot and insert it again properly.