DECAN_F2_Service(Eng_Ver1).pdf - 第432页

17-20 Fast & Flexible Chip Shooter DECAN F2 Service Manual E070C Optimizer Error [Cause]  The CNT0 nozzle is registered to the ANC.  The part lead width is incorrectly set. [How to Check]  Check whether the CNT0 n…

100%1 / 604
17-19
Troubleshooting
When running the optimizer, check error messages and check whether there are any
parts whose size exceeds the part size that can be recognized by the camera.
[Measures]
Change the type of camera recognizing parts to one that can recognize the
corresponding part and run the optimizer.
E0709 When running the optimizer, the Download Manager Mode is disabled
[Cause]
The MMI system file is infected by a virus.
[How to Check]
Perform HDD recovery and reinstall the MMI and then check whether the same
problem occurs.
[Measures]
Perform HDD recovery and reinstall the MMI.
E070A After running the optimizer, exit the MMI by force
[Cause]
The Sopti.exe file is infected by a virus or an optimizer file whose version does not
match the currently installed MMI exists.
[How to Check]
Perform HDD recovery and reinstall the MMI, and then check whether the same
problem occurs.
[Measures]
Perform HDD recovery and reinstall the MMI. Then install an optimizer that matches
the MMI version.
E070B An error occurred when running the optimizer after importing the Txt file (A
Windows system error happened during the operation. Please save the PCB file and
reboot the machine.
[Cause]
After registering the part, the part data is not saved.
[How to Check]
After checking error messages when running the optimizer, check whether there is any
unregistered part data.
[Measures]
After registering the unregistered part data, save it.
17-20
Fast & Flexible Chip Shooter DECAN F2 Service Manual
E070C Optimizer Error
[Cause]
The CNT0 nozzle is registered to the ANC.
The part lead width is incorrectly set.
[How to Check]
Check whether the CNT0 nozzle is registered to the ANC.
Check whether there are any parts whose lead width exceeds the requirement of the
camera regarding the lead width.
[Measures]
Remove the CNT0 nozzle on the ANC.
Modify the part lead width.
E070D An error occurred that the front gantry fiducial camera recognized the fiducial mark
of the PCB transferred to the work station of the rear lane.
[Cause]
After the position of the Place Stopper had been changed, the stopper position was not
taught correctly.
[How to Check]
Check whether the position of the Place Stopper is correct and move its position to
check whether the same problem occurs.
[Measures]
Change the position of the Place Stopper.
E070E Exceeded the bad mark recognition range
[Cause]
After the position of the Place Stopper had been changed, the stopper position was not
taught correctly.
[How to Check]
Check whether the position of the Place Stopper is correct and move its position to
check whether the same problem occurs.
[Measures]
Change the position of the Place Stopper.
E070F The fiducial mark recognition position of the front and rear PCBs is different
[Cause]
The position of the Place Stopper is incorrect.
[How to Check]
17-21
Troubleshooting
Check whether the position of the Place Stopper is correct and move its position to
check whether the same problem occurs
[Measures]
Set the front/rear stopper again and perform conveyor calibration referring to the
Administrators Guide.
E0710 The confirmation window was not displayed when the fiducial mark recognition error
occurred
[Cause]
The <Use Manual Fiducial Teach> was not applied
[How to Check]
Select the General setup tab dialog box in the Preference submenu of the 'Sys. Setup'
menu and check whether the <Use Manual Fiducial Teach> check box is selected
[Measures]
After selecting the General setup tab dialog box in the Preference submenu of the 'Sys.
Setup' menu, select the <Use Manual Fiducial Teach> check box to apply the
corresponding function.
E0711 Failed to recognize the second PCB fiducial mark
[Cause]
Since the overall illumination is too bright and the area margin is set too widely, the
fiducial mark interferes with the mark nearby
[How to Check]
Perform a fiducial mark recognition test to check whether the brightness of the
illumination is appropriate. Then check whether the fiducial mark interferes with the
one nearby due to incorrect setup of the mark search area
[Measures]
Adjust the illumination brightness or change the area margin.
E0712 An error occurred when using an array fiducial
[Cause]
Incorrect system constant setup
[How to Check]
Check whether the No. 72 System Constant, ‘OPT FID DIST CHK’, is ‘0’
[Measures]
Set the OPT FID DIST CHK to '0'. (No. 72 System Constant)