DECAN_F2_Service(Eng_Ver1).pdf - 第434页

17-22 Fast & Flexible Chip Shooter DECAN F2 Service Manual E0713 Warning that t he camera is not installed. CAM:2 … [Cause]  The MMI system file is damaged. [How to Check]  Check the camera setup in the Came ra sub…

100%1 / 604
17-21
Troubleshooting
Check whether the position of the Place Stopper is correct and move its position to
check whether the same problem occurs
[Measures]
Set the front/rear stopper again and perform conveyor calibration referring to the
Administrators Guide.
E0710 The confirmation window was not displayed when the fiducial mark recognition error
occurred
[Cause]
The <Use Manual Fiducial Teach> was not applied
[How to Check]
Select the General setup tab dialog box in the Preference submenu of the 'Sys. Setup'
menu and check whether the <Use Manual Fiducial Teach> check box is selected
[Measures]
After selecting the General setup tab dialog box in the Preference submenu of the 'Sys.
Setup' menu, select the <Use Manual Fiducial Teach> check box to apply the
corresponding function.
E0711 Failed to recognize the second PCB fiducial mark
[Cause]
Since the overall illumination is too bright and the area margin is set too widely, the
fiducial mark interferes with the mark nearby
[How to Check]
Perform a fiducial mark recognition test to check whether the brightness of the
illumination is appropriate. Then check whether the fiducial mark interferes with the
one nearby due to incorrect setup of the mark search area
[Measures]
Adjust the illumination brightness or change the area margin.
E0712 An error occurred when using an array fiducial
[Cause]
Incorrect system constant setup
[How to Check]
Check whether the No. 72 System Constant, ‘OPT FID DIST CHK’, is ‘0’
[Measures]
Set the OPT FID DIST CHK to '0'. (No. 72 System Constant)
17-22
Fast & Flexible Chip Shooter DECAN F2 Service Manual
E0713 Warning that the camera is not installed. CAM:2 …
[Cause]
The MMI system file is damaged.
[How to Check]
Check the camera setup in the Camera submenu of the Sys.Setup menu.
[Measures]
Reinstall the MMI software.
E0714 The DLL file cannot be found while executing the MMI
[Cause]
The MMI system file is damaged
Infected by a virus
[How to Check]
Perform HDD recovery and reinstall the MMI. Then check whether the same problem
occurs
Temporarily install an anti-virus program and check whether the file was infected by a
virus. (Delete the temporarily installed anti-virus program after inspection.)
[Measures]
Perform HDD recovery and reinstall the MMI.
If it is confirmed that the file was infected by a virus, remove the virus and then delete
the anti-virus program. If a problem occurs after booting or the system malfunctions,
perform HDD recovery
E015 When opening a file, even though the file name exists, the file is not opened
[Cause]
The MMI or Windows system file is damaged
[How to Check]
Perform a virus check of the HDD to check whether it has been infected. Format the
HDD and perform HDD recovery. Then reinstall the MMI and check whether the same
problem occurs
[Measures]
Format and recover the HDD and then reinstall the MMI.
E0716 When opening the PCB file, the PCB file in a certain folder was not opened
[Cause]
The PCB file created in the higher MMI version is opened in the lower version
[How to Check]
17-23
Troubleshooting
Check whether the MMI versions of the machines in the line are same
[Measures]
Maintain the MMI SW version of the machines in the same line to be identical.
E0717 The buzzer sounds continuously with the MMI being closed after a message was
generated during operation
[Cause]
Infected by a virus
[How to Check]
Perform a virus check of the HDD to check whether it has been infected. Format the
HDD and perform HDD recovery. Then reinstall the MMI and check whether the same
problem occurs
[Measures]
After removing the memory of the SBC board, insert it again, and insert the SBC
board into the vision board connector properly.
Then insert the vision board into the back plane board slot and after booting it,
perform a virus check to determine whether it is infected by a virus. After formatting
the HDD, perform HDD recovery and reinstall the MMI.
E0718 When booting the machine, the login password input window is displayed. When a
password is inputted, the ‘Incorrect Password’ message is indicated and Windows is
not booted
[Cause]
The Windows booting file is infected by a virus
[How to Check]
Perform a virus check of the HDD to check whether it has been infected. Format the
HDD and perform HDD recovery. Then reinstall the MMI and check whether the same
problem occurs
[Measures]
Format and recover the HDD and then reinstall the MMI.
E0719 If the tape feeder is set to ‘None’, the tape feeder is set at the slot below it
[Cause]
Infected by a virus
[How to Check]
Perform a virus check of the HDD to check whether it has been infected. Format the
HDD and perform HDD recovery. Then reinstall the MMI and check whether the same
problem occurs