DECAN_F2_Service(Eng_Ver1).pdf - 第500页
17-88 Fast & Flexible Chip Shooter DECAN F2 Service Manual Replace the board. E1404 AE-Link communication error - I/O Node "0" [Cause] Defective NICO board operation [How to Check] After checking whe …

17-87
Troubleshooting
NODE 11: BF SILL
NODE 12: BF Camera Switch Board
NODE 13: BF Head Memory Board
NODE 14: BR Camera Switch Board
NODE 15: BR Head Memory Board
[Measures]
Replace the board of the corresponding node.
E1402 Defective operation of the Can communication board
[Cause]
Defective connection of the Can cable
[How to Check]
Check whether the I/O of the specific board works properly
Check the LED light and power supply of the corresponding board
Check the Can communication cable
Replace the corresponding board
[Measures]
Check whether the I/O works properly.
Check the LED light and power supply.
Check the connection of the Can communication cable.
Replace the board.
E1403 Abnormal Can communication board operation and communication error
[Cause]
Abnormal Can node setup
[How to Check]
Check whether the I/O of the specific board works properly
Check the LED light and power supply of the corresponding board
Check the node select switch of the corresponding board
Check the Can communication cable
Replace the corresponding board
[Measures]
Check whether the I/O works properly.
Check the LED light and power supply.
Check the Can communication cable.

17-88
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Replace the board.
E1404 AE-Link communication error - I/O Node "0"
[Cause]
Defective NICO board operation
[How to Check]
After checking whether the NCIO board is inserted into the back plane board slot,
check whether the NCIO board cable is properly connected
Replace the NCIO board and check whether the same problem occurs
[Measures]
Insert the NCIO board into the back plane board slot or connect the NCIO board cable
again.
Replace the NCIO board.
E1405 Defective communication with the machine at the previous stage
[Cause]
Incorrect MMI setup
Defective SEMEA cable
Defective Base Control board
Defective I/F protocol with the previous machine
[How to Check]
Defective base control board
Check the SMEMA cable connection
Check the I/F connection with the previous machine (supplied by others) (contact
type, SEMEA type, etc.)
Replace the general I/O board and check whether the same problem occurs
[Measures]
Check the SMEMA I/F setup of the MMI setup.
Check the SMEMA cable connection.
Check the I/F connection with the previous machine (supplied by others).
Replace the general IO board.
E1406 Defective communication with the machine at the next stage
[Cause]
Incorrect MMI setup
Defective SEMEA cable

17-89
Troubleshooting
Defective Base Control board
Defective I/F protocol with the next machine
[How to Check]
Check the I/F setup of the MMI setup
Check the SMEMA cable connection
Check I/F connection with the next machine (supplied by others) (contact type,
SEMEA type, etc.)
Replace the conveyor I/F board
[Measures]
Check the SMEMA I/F setup of the MMI setup.
Check the SMEMA cable connection.
Check the I/F connection with the next machine (or the machine supplied by other
company).
Replace the general IO board.