13-19 Software [DUAL_GANTRY] 2R_Fly_Camera_ T ype= 10 2R fiducial camera type 2R_Fix_Camera_ T ype= 10 2R fly camera type 2R_Fid_Camera_ T ype= 1 2R fix camera type 2F_SWT rigger= 1 Whether to use the 2F sof tware trigge…

13-18
Fast & Flexible Chip Shooter DECAN F2 Service Manual
[DUAL_GANTRY] 1F_Fid_Camera_
Type= 1
1F fiducial
camera type
1F_Fly_Camera_
Type= 10
1F fly camera
type
1F_Fix_Camera_
Type= 10
1F fix camera
type
1R_Fly_Camera_
Type= 10
1R fiducial
camera type
1R_Fix_Camera_
Type= 10
1R fly camera
type
1R_Fid_Camera_
Type= 1
1R fix camera
type
1F_SWTrigger= 1 Whether to use
the 1F software
trigger
1R_SWTrigger=
1
Whether to use
the 1R software
trigger
1F_NotifyFirstDM
ADone= 1
Improvement of
the image
transmission
sequence of
the fly camera
1R_NotifyFirstDM
ADone= 1
Improvement of
the image
transmission
sequence of
the fly camera
2F_Fid_Camera_
Type= 1
2F fiducial
camera type
2F_Fly_Camera_
Type= 10
2F fly camera
type
2F_Fix_Camera_
Type= 10
2F fix camera
type
Classification
Item and Default
Value
Description
Remarks

13-19
Software
[DUAL_GANTRY] 2R_Fly_Camera_
Type= 10
2R fiducial
camera type
2R_Fix_Camera_
Type= 10
2R fly camera
type
2R_Fid_Camera_
Type= 1
2R fix camera
type
2F_SWTrigger= 1 Whether to use
the 2F software
trigger
2R_SWTrigger=
1
Whether to use
the 2Rsoftware
trigger
2F_NotifyFirstDM
ADone= 1
Improvement of
the image
transmission
sequence of
the fly camera
2R_NotifyFirstDM
ADone= 1
Improvement of
the image
transmission
sequence of
the fly camera
Classification
Item and Default
Value
Description
Remarks

13-20
Fast & Flexible Chip Shooter DECAN F2 Service Manual
[HEAD] 1F_Fix_Camera_
HeadNum= 10
Number of
spindles
viewed by one
of the 1F fix
cameras
1R_Fix_Camera_
HeadNum= 10
Number of
spindles
viewed by one
of the 1R fix
cameras
2F_Fix_Camera_
HeadNum= 10
Number of
spindles
viewed by one
of the 2F fix
cameras
2R_Fix_Camera_
HeadNum= 10
Number of
spindles
viewed by one
of the 2R fix
cameras
[SM321] LiveThread = 1
Exclusively
used for
SM300
SWTrigger= 0
Exclusively
used for
SM300
NotifyFirstDMAD
one= 1
Exclusively
used for
SM300
[UNIT_TEST] TestImageDir =
D:\\TestImages\\
Image saving
folder
For internal test by a
developer
[CAMERA] Cam0=1 1F-Fid1
camera type
Cam1=10 1F-Fix1
camera type
Classification
Item and Default
Value
Description