DECAN_F2_Service(Eng_Ver1).pdf - 第504页
17-92 Fast & Flexible Chip Shooter DECAN F2 Service Manual 17.3.18. I/O signal and boar d power supply (E16) E1600 Defective power supply [Cause] Defective power supply (24V) [How to Check] Check the input voltag…

17-91
Troubleshooting
Replace the NCIO board and check the connector
[Measures]
Perform a manual feeder operation test in the feeder base I/O window.
Replace the cart control board and check the connection between the cable and
connector.
E1503 Vision loading error and Visframe error occurred
[Cause]
Defective vision board
[How to Check]
Check whether the vision board is properly inserted into the back plane slot
Check whether the SBC board is properly inserted into the vision board connector
Replace the vision board and SBC board
Reinstall the Windows and MMI
[Measures]
Insert the vision board into the back plane board slot properly.
Insert the SBC board into the vision board connector properly.
Replace the vision board and SBC board.
Perform HDD recovery and reinstall the MMI.
E1504 CAN communication error or Vision communication error occurs
[Cause]
Defective PCI I/O and CAN Master board
(Applicable only to SM series machines excluding the DECAN F2, SLM, SM471 and
SM48X.)
Defective Axis I/O board and SAMC board
(Applicable only to the DECAN F2, SLM, SM471 and SM48X machines.)
[How to Check]
Check the PCI I/O board.
Check the CAN Master board.
Check the SAMC board.
[Measures]
Replace the CAN Master board, CAN PCI board and SAMC board.

17-92
Fast & Flexible Chip Shooter DECAN F2 Service Manual
17.3.18. I/O signal and board power supply (E16)
E1600 Defective power supply
[Cause]
Defective power supply (24V)
[How to Check]
Check the input voltage of the board for defective operation (24V)
Replace the board and check whether it operates properly
Replace the power supply
[Measures]
Replace the DC power supply unit.
E1601 Fuse cutoff
[Cause]
Fuse cutoff
[How to Check]
Check the fuse
[Measures]
Replace the fuse.
Cause Description Remarks
Specific board does not
work
Defective power supply E1600
Fuse cutoff E1601

17-93
Troubleshooting
17.3.19. Abnormal monitor (E17)
E1700 Monitor screen does not appear
[Cause]
Monitor screen does not appear (‘No signal’ is not indicated)
[How to Check]
Check the monitor power and signal cable
Check the CPU box power supply (12V)
Replace the motor.
[Measures]
Check the monitor power supply and signal cable.
Check the CPU box power supply.
Replace the motor.
E1701 Although the system is booted, the screen does not appear on the monitor
[Cause]
Although the system is booted, the screen does not appear on the monitor
[How to Check]
Check whether the monitor cable is properly connected to the vision board.
Replace and check the monitor cable.
Replace the monitor.
[Measures]
Check whether the monitor cable is properly connected to the vision board.
Replace and check the monitor cable.
Replace the monitor.
E1702 Although the system is booted, the monitor screen is discolored
[Cause]
Although the system is booted, the monitor screen is discolored
[How to Check]
Cause Description Remarks
Abnormal monitor Monitor screen does not appear E1700
Although the system is booted, the screen does not
appear on the monitor
E1701
Although the system is booted, the monitor screen is
discolored
E1702