DECAN_F2_Service(Eng_Ver1).pdf - 第323页
13-53 Software Align / Mount 62 Sys Fly outer Level Use 519 Const Set t he control algorithm for the outer illuminatio n of the fly camera. 68 Small Comp Method Use 15 Const Method related to the Small Comp. 70 Small Com…

13-52
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Vacuum 63 Sys Head Vac Delay Use 5 msec
Time delay from the Z Pulse End until the Vacuum Sol Off
signal is generated.
64 Sys Head Vac Time Use 5
msec Period of time from Vacuum Sol Off until the vacuum is
released.
65 Sys Head Vac Gen
Time
Use
20
msec Period of time from Vacuum Sol On until the vacuum is
created.
66 Sys Head Vac Rel
Time
Use 21
msec Period of time from Vacuum Sol Off until the vacuum
release is stabilized.
67 Sys Head Vac Time2 Reser
ved
170
msec Time of minimum variation when releasing the vacuum.
71 Sys Offset Vac Use 40 um
For the Z measurement using a vacuum, the difference
between the measurement vale and actual value.
Difference in measurement value when using the CN040.
96 Vac Close Detect
ABS
Use
613 mmHg
Absolute value based on when the nozzle is clogged
(used for Z offset, etc.).
97 Vac Close Detect Diff
Use
60 mmHg
Difference in measurement value based on when the
nozzle is clogged (used for Z offset, etc.)
Module No Name Div Value Unit Description

13-53
Software
Align /
Mount
62
Sys Fly outer Level Use
519
Const Set the control algorithm for the outer illumination of the
fly camera.
68 Small Comp Method
Use
15
Const Method related to the Small Comp.
70 Small Comp Size
Use
620 um
Standard size of the Small Comp.
72 Very Small Comp
Method
Use
7
Const Method related to the Very Small Comp.
73 Very Small Comp
Size
Use
380 um
Standard size of the Very Small Comp.
94 Fly Inspr Method
Use
3
Const 0: Recognition by the fly camera after rotation
(Recognition using placement angle).
1: Rotation after recognition by the fly camera (0 degree
recognition).
2: Rotation after recognition by the fly camera.
However, the fly camera will recognize a part after
rotating in the case of a 45° feed angle and FineGrab.
3: Rotation after recognition by the fly camera.
However, the fly camera will recognize a part after
rotating in the case of a 45° feed angle, FineGrab and
FinePitch.
Module No Name Div Value Unit Description

13-54
Fast & Flexible Chip Shooter DECAN F2 Service Manual
HW 17 Use UPS
Use
0
Const 0: UPS not used. 1: UPS used
18 CE Type
Use
0
Const 0: CE not applied
1: CE applied
XY Move 40 Sys Delay XY1
Use
20
msec Delay used for general XY movement
41 Sys Delay XY2
Use
0
msec Delay used for XY movement for part pickup
42 Sys Delay XY3
Use
8
msec Delay (polling) used for XY movement for part placement
43 Sys Delay XY4
Use
40
msec Delay used for XY movement requiring high precision
44 Sys Backlash XY
Use
5um
Zone used for the XY backlash prevention algorithm
Z Move 45 Sys Delay Z1
Use
0
msec Delay used for general Z movement
48 Sys Delay Z4
Use
20
msec Delay used for Z movement requiring high precision
81 Escape Z Fast
Use
21000 um
In the case of the FLY_SS cycle, this refers to the Z-axis
position (between 6000 ~ 45000) at which the mirror
starts to come in after the Z-axis has picked up a part.
82 Escape Z Mnt Fast
Use
2500 um
In the case of the FLY_SS cycle, this refers to the Z-axis
height (between 1000 ~ 6000) to which the XY can move
when it moves up after the Z-axis has performed part
placement.
Values other than these will be processed as 8000.
Module No Name Div Value Unit Description